30
FPQ41 Superminor Issue 1
6.2.2
Tank exterior
Use diluted detergent and a clean cloth to wipe
down the outside of the tank.
Dry the outside of the tank after cleaning.
6.2.3
Tank interior
Follow the instructions in section 4.9 to empty
the coolant from the tank.
Remove the power plug from the wall to
disconnect the Superminor from the power
supply.
Remove the tank from the frame (section 4.10.1).
Scrape out all debris from inside the tank and
dispose of the debris according to your company
procedures.
Use a steam cleaner to clean the inside of the
tank.
Note
If you do not have a steam cleaner, you
can use a warm-water hose or pressure
spray to wash out the inside of the tank.
During and after cleaning - make sure
that any oily residue or water is
disposed of according to your
company procedures. Do not allow it
to enter normal drains.
Replace the tank into the frame (section 4.10.2).