FR200F series Special Purpose Inverter
- 40 -
Ten’s place: interrupt
operation, and then
start the selection
0: continue from
stop step(restart
moment)
1: continue from
stop step and
moment
2: re-operation
starts from 0 step
Hundred’s place:
power-off memory
selection
0: power-off no
memory
1: power-off
memory
Thousand’s place:
Simple PLC running
time
0:s (second
)
1:min (minute
)
Ten thousand’s place:
Length unit
0:0.1m
1:1m
H00.34
Running Mode
0: Linear mode
0
×
4022H
1: Gradual mode
2: Length mode
H00.35
Speed Ratio
0.00
~
600.00RPM/Hz
30.00RPM/
Hz
△
4023H
H00.36
Current Rev
0
~
60000RPM
0RPM
⊙
4024H
H00.37
Average Speed
0
~
60000RPM
0RPM
⊙
4025H
H00.38
Average Speed Hz
0.00
~
600.00Hz
0Hz
⊙
4026H
H00.39
Roller speed
measurement
0:Calculated based on
speed
1:Calculated based on
pulse input(DI7)
0
×
4027H
H00.40
Roller diameter
0.0~6000.0mm
50.0mm
△
4028H
H00.41
Roller per revolution
0~100
1
△
4029H
H00.42
Current line speed
0.0~6000.0m/min
0.0m/min
⊙
402AH
H00.43
Completed length
0~60000m
0m
⊙
402BH
H00.44
Percent length
completed
0.0~100.0%
0.0%
⊙
402CH
3.3 H00 Textile-specific function group explaination
H00.00
Control of Textile Machine
0:Invalid
1
×
1:Valid
0: Invalid
General inverter
1:Valid
Special purpose inverter for textile machine, H00 group valid.
H00.01
Multi-steps 0
0.00
~
600.00Hz
0.00Hz
△
H00.02
Multi-steps 1
0.00
~
600.00Hz
0.00Hz
△