Dear user, 
 
 
This manual has been designed to provide you with all the information you need 
to install and use your FRECON SPEED DRIVE. Feel free to contact us for any 
further information you may require concerning special applications beyond the 
scope of this manual. 
Please keep this manual in a safe place for future reference. 
 
 
 

FRECON  

 
 
 
 
 

SAFETY PRECAUTIONS 
 

 

 
DANGER:   The voltages present in the supply cables, the output cables and terminals, the control 
                     power supply  wiring and in certain internal parts of causing severe electric shock and 
                    may be lethal ! 
 
WARNING:  Whenever the drive has been energised

;

 it must be isolated before work may continue. 

                    A period of five minutes must elapse after isolation to allow the internal capacitors to 
                    discharge fully. Until the  discharge period has passed dangerous voltages may be  
                    present within the drive. 
 
Persons supervising and performing electrical installation must  be suitably qualified and 
competent in these duties, and should be given the opportunity to study this manual before work is 
started.
 

 

 

 
 
 
 
TESTED 

Committed to quality, FRECON individually test each FRECON SPEED DRIVE to  ensure reliable 
performance for the user. All units have passed FRECON´S quality control standards and conform 
within tolerance to the enclosed specifications. 
 

 
 
 
 
 

ENTIRE CONTENS COPYRIGHT FRECON s.r.o. ALL RIGHTS RESERVED, REPRODUCTION IN WHOLE OR IN PARTS WITHOUT PERMISSION IS PROHIBITED. 
FRECON FIA-L  IS A  PRODUCT OF  FRECON

 

Содержание FIA-L110

Страница 1: ...CZECH REPUBLIC tel 420 241 71 32 44 45 fax 420 241 72 10 52 E mail info frecon cz http www frecon cz FRECON FIA L18 37 55 75 110 150 220 250 PROGRAMMABLE SPEED DRIVES FOR STANDARD AC INDUCTION MOTORS...

Страница 2: ...before work may continue A period of five minutes must elapse after isolation to allow the internal capacitors to discharge fully Until the discharge period has passed dangerous voltages may be presen...

Страница 3: ...W up to 500Hz Apparent power kVA 0 6 1 0 1 4 1 6 2 2 2 8 4 0 4 5 Overload 150 30 sec Nominal current A 1 4 2 4 3 0 4 0 5 5 7 0 10 0 11 3 Modulation PWM 18kHz V f characteristic adjustable Control logi...

Страница 4: ...control power supply wiring and in certain internal parts of the drive are capable of causing severe electric shock and may be lethal WARNING Whenever the drive has been energised it must be isolated...

Страница 5: ...andard cable to both the motor earth terminal and the drive earth terminal Installations with long cable runs to the motor i e above approx 30 m may need the addition of motor line chokes to prevent n...

Страница 6: ...eter 2 20 k recommended value 10 k Logic inputs run stop control switch or PLC output forward reverse control switch or PLC output Input voltage min 15 VDC Input current approx 8 5 mA 24 VDC nominal 2...

Страница 7: ...is set by parameter ACC refer to chapter 9 section 1 disconnect 24 V DC from the terminal 3 The motor will ramp or coast to a stop Deceleration is set by parameter DEC stopping mode is set by paramete...

Страница 8: ...led and all parameter values can be changed from the keypad refer to user manual for the MINITERMINAL 8 Reset of the drive after a trip signal Two modes are available short time disconnecting of the d...

Страница 9: ...age FOUT 6 8 FBAS U7 32 93 VMAX output voltage FOUT 7 8 FBAS CINP 0 1 2 3 reference input selection CSTP 0 1 stopping mode selection CRTR 0 1 reset mode selection SET support parameter for user set pr...

Страница 10: ...the filter follow the instructions in FIG 4 FIG 4 The filter cubicle is necessary to install near of the drive NOTE Connections must be made with the short length of screened cables If these cables ar...

Отзывы: