  Displayed values and adjustable drive parameters. 
 

MENU

 

Adjustment range

 

Description

 

FOUT 

0 ... f

max

 (Hz) 

actual output frequency 

FSET 

0 ... f

max

 (Hz) 

required output frequency 

F0 

0 - 125 Hz 

required output frequency  

(0% analogue input signal) 

F100 

0 - 125 Hz 

required output frequency  

(100% analogue input signal) 

FERR 

0 -125 Hz 

required output frequency  

(analogue input signal non-present) 

ACC 

0,5 - 500 Hz/s 

FOUT acceleration 

DEC 

0,5 - 500 Hz/s 

FOUT deceleration 

FBAS 

25 - 241 Hz 

base frequency 

U0 

0 - 22% V

MAX

 output 

voltage 

(FOUT = 0 Hz) 

U1 

1 - 30% V

MAX

 output 

voltage 

(FOUT = 1/8 FBAS) 

U2  

2 - 40% V

MAX

 output 

voltage 

(FOUT = 2/8 FBAS) 

U3 

4 - 50% V

MAX

 output 

voltage 

(FOUT = 3/8 FBAS) 

U4 

6 - 60% V

MAX

 output 

voltage 

(FOUT = 4/8 FBAS) 

U5 

10 - 70% V

MAX

 output 

voltage 

(FOUT = 5/8 FBAS) 

U6 

16 - 81% V

MAX

 output 

voltage 

(FOUT = 6/8 FBAS) 

U7 

32 - 93% V

MAX

 output 

voltage 

(FOUT = 7/8 FBAS) 

CINP 

0, 1, 2, 3 

reference input selection 

CSTP 

0,1 

stopping mode selection 

CRTR 

0,1 

reset mode selection  

SET 

 

support parameter for user set programming 

 

    For more information: refer to user manual for the MINITERMINAL. 

 

9.2. FRECON TELECONTROL

 - remote control unit 

 Functions: 

- fault LED indication 
- speed control    : potentiometer 
- run/stop             : change-over switch 
- forward/reverse : change-over switch 

  Dimensions     : 110 x 80 x 55 mm (h x w x d) 

  Mounting: externally anywhere convenient at a distance permitted by a maximum cable length of 

50m from the drive to the TELECONTROL. 

 

9.3. Braking unit 

A decelerating AC motor regenerates energy into the inverter drive. This energy can only be dissipated 
within the drive, it cannot be returned to the AC supply by the FRECON unit. If the regenerated power 
is less than approx. 4% of rated drive power, the braking unit is not necessary to use. 

 

Connection:  terminals -B, +B (FIG. 1)

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание FIA-L110

Страница 1: ...CZECH REPUBLIC tel 420 241 71 32 44 45 fax 420 241 72 10 52 E mail info frecon cz http www frecon cz FRECON FIA L18 37 55 75 110 150 220 250 PROGRAMMABLE SPEED DRIVES FOR STANDARD AC INDUCTION MOTORS...

Страница 2: ...before work may continue A period of five minutes must elapse after isolation to allow the internal capacitors to discharge fully Until the discharge period has passed dangerous voltages may be presen...

Страница 3: ...W up to 500Hz Apparent power kVA 0 6 1 0 1 4 1 6 2 2 2 8 4 0 4 5 Overload 150 30 sec Nominal current A 1 4 2 4 3 0 4 0 5 5 7 0 10 0 11 3 Modulation PWM 18kHz V f characteristic adjustable Control logi...

Страница 4: ...control power supply wiring and in certain internal parts of the drive are capable of causing severe electric shock and may be lethal WARNING Whenever the drive has been energised it must be isolated...

Страница 5: ...andard cable to both the motor earth terminal and the drive earth terminal Installations with long cable runs to the motor i e above approx 30 m may need the addition of motor line chokes to prevent n...

Страница 6: ...eter 2 20 k recommended value 10 k Logic inputs run stop control switch or PLC output forward reverse control switch or PLC output Input voltage min 15 VDC Input current approx 8 5 mA 24 VDC nominal 2...

Страница 7: ...is set by parameter ACC refer to chapter 9 section 1 disconnect 24 V DC from the terminal 3 The motor will ramp or coast to a stop Deceleration is set by parameter DEC stopping mode is set by paramete...

Страница 8: ...led and all parameter values can be changed from the keypad refer to user manual for the MINITERMINAL 8 Reset of the drive after a trip signal Two modes are available short time disconnecting of the d...

Страница 9: ...age FOUT 6 8 FBAS U7 32 93 VMAX output voltage FOUT 7 8 FBAS CINP 0 1 2 3 reference input selection CSTP 0 1 stopping mode selection CRTR 0 1 reset mode selection SET support parameter for user set pr...

Страница 10: ...the filter follow the instructions in FIG 4 FIG 4 The filter cubicle is necessary to install near of the drive NOTE Connections must be made with the short length of screened cables If these cables ar...

Отзывы: