7. Operating procedures  

 

CHECK THAT : 

*    The motor rating is compatible with the drive rating 
*    The motor winding connection is compatible with the drive output voltage  
       (refer to chapter 5

;

 section 1.3.) 

*    AC input power circuit breaker of the correct rating is installed upstream on the low voltage 
      switch - board  (refer to chapter 5, section 1.2.) 
*    the drive is firmly attached in an upright position and is properly ventilated 

 

7.1. Procedure  I 

- remote (external) control, without using MINITERMINAL (control pod)  

 

     and TELECONTROL (remote control unit) 

  connect the control cable to terminal board (shown in FIG 2) 

  put the AC input power circuit breaker in "ON" position - the red "POWER" light goes on. 

 

In the event of a fault, the red "FAILURE" light goes on. 

 

7.1.1. Speed control 

  potentiometer : terminals 

8, 9, 11

 

                                   or 

  voltage signal : terminals 

9, 11 

                                   or 

  current signal : terminals 

10, 11 

 

7.1.2. "Run/stop" 

  connect 24 V DC to the terminal 

3

 (control switch or PLC output) : 

 

The motor will start and run up to the set speed. 

 

Acceleration is set by parameter "ACC" (refer to chapter 9.

;

 section 1.) 

  disconnect 24 V DC from the terminal 

3

 : 

 

The motor will ramp or coast to a stop. 

 

Deceleration is set by parameter "DEC", stopping mode is set by parameter " CSTP "  

 

(refer to chapter 9

;

 section 1. and user manual for the MINITERMINAL - control pod) 

 

7.1.3. " Fwd/rev" - Forward/reverse  

  connect 24 V DC to the terminals

 4 

and

 3

 simultaneously (control switch or PLC output) : 

Running motor - motor will ramp by set decel time to a stop and then will run up by set accel time 
                           in a reverse direction to the required speed 
Motor is stopped - motor will start and run up by set accel time in a reverse direction to the  
                              required speed 

  disconnect 24 V DC from the terminal 

4

 (24V DC is connected to the terminal 

3

) : 

 

The motor will ramp to a stop and then will run up in a forward direction to the set speed. 

 

 

7.2. Procedure II 

- remote (external) control, using TELECONTROL - remote control unit (option) 

  connect the control cable to the terminal boards at the drive and the TELECONTROL (shown in FIG 

3) 

 
 
 
 
 
 
 
 
 
 
 
                            

FIG 3 

 

  put the AC input power circuit breaker in "on" position - the red "Power" light goes on. 

 

In the event of a fault

;

 the red "FAILURE" light goes on. 

 
 

F

R

E

C

O

N

  

T

E

L

E

C

O

N

T

R

O

L

/F

IA

F

R

E

C

O

N

  

 F

IA

-L

Содержание FIA-L110

Страница 1: ...CZECH REPUBLIC tel 420 241 71 32 44 45 fax 420 241 72 10 52 E mail info frecon cz http www frecon cz FRECON FIA L18 37 55 75 110 150 220 250 PROGRAMMABLE SPEED DRIVES FOR STANDARD AC INDUCTION MOTORS...

Страница 2: ...before work may continue A period of five minutes must elapse after isolation to allow the internal capacitors to discharge fully Until the discharge period has passed dangerous voltages may be presen...

Страница 3: ...W up to 500Hz Apparent power kVA 0 6 1 0 1 4 1 6 2 2 2 8 4 0 4 5 Overload 150 30 sec Nominal current A 1 4 2 4 3 0 4 0 5 5 7 0 10 0 11 3 Modulation PWM 18kHz V f characteristic adjustable Control logi...

Страница 4: ...control power supply wiring and in certain internal parts of the drive are capable of causing severe electric shock and may be lethal WARNING Whenever the drive has been energised it must be isolated...

Страница 5: ...andard cable to both the motor earth terminal and the drive earth terminal Installations with long cable runs to the motor i e above approx 30 m may need the addition of motor line chokes to prevent n...

Страница 6: ...eter 2 20 k recommended value 10 k Logic inputs run stop control switch or PLC output forward reverse control switch or PLC output Input voltage min 15 VDC Input current approx 8 5 mA 24 VDC nominal 2...

Страница 7: ...is set by parameter ACC refer to chapter 9 section 1 disconnect 24 V DC from the terminal 3 The motor will ramp or coast to a stop Deceleration is set by parameter DEC stopping mode is set by paramete...

Страница 8: ...led and all parameter values can be changed from the keypad refer to user manual for the MINITERMINAL 8 Reset of the drive after a trip signal Two modes are available short time disconnecting of the d...

Страница 9: ...age FOUT 6 8 FBAS U7 32 93 VMAX output voltage FOUT 7 8 FBAS CINP 0 1 2 3 reference input selection CSTP 0 1 stopping mode selection CRTR 0 1 reset mode selection SET support parameter for user set pr...

Страница 10: ...the filter follow the instructions in FIG 4 FIG 4 The filter cubicle is necessary to install near of the drive NOTE Connections must be made with the short length of screened cables If these cables ar...

Отзывы: