![Franklin Electric SubDrive100 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/franklin-electric/subdrive100/subdrive100_installation-manual_2328787020.webp)
Specifications – SubDrive150
Input from
Power Source
(single-phase)
Voltage
190-260 VAC
Frequency
60/50 Hz
Current (max)
23 Amps (RMS)
Power Factor
1.0 (constant)
Power (idle)
65 Watts
Power (max)
4600 Watts
Output to Motor
(three-phase)
Voltage
Adjusts with Frequency
Frequency Range
1.1 kW pump
30 - Hz
1.5 kW pump
30 - Hz
2.2 kW pump
30 - Hz
Current (max)
10.9 Amps (RMS, each phase)
Pressure Setting
Factory Preset
3.4 bar
Adjustment Range
1.7 -5.5 bar
Operating
Conditions
(A)
Drive
IP10
Pressure sensor
IP24
Temperature (at 230 VAC input)
-25 to 50
o
C
Relative Humidity
10-95%, non-condensing
Controller Size
(B)
(approximate)
indoor IP10
42 x 32 x 23 cm
7.94 kg
For Use With
(C)
Pump (50 Hz)
1.1 kW (default)
1.5 kW
2.2 kW
Motor (three-phase)
234316 - series (2.2 kW)
A. Operating temperature is specified at full output power when installed as described in Controller Location
Selection on pg. 11.
B. Refer to pg. 18 for detailed Mounting Dimensions.
C. If a pump other than the default rating is used, refer to pg. 8 for Drive Configuration.
Notes:
A
F
E
C
D
B
G
H
Mounting Dimensions
SubDrive75/100/150:
A
B
C
D
E
F
G
H
Dimension (cm)
13.4
29.2
14
24.8
32.5
35.6
2.9
1.3
Conduit Sizes
-
-
-
-
-
-
1.9
-
* Use knock-outs as required.
18