![Franklin Electric SubDrive100 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/franklin-electric/subdrive100/subdrive100_installation-manual_2328787015.webp)
12
B
la
ck
R
ed
L2
From Power Source
L1
(In
pu
t)
ON
12
34
SW1
L2
Sensor
Connection
Output to Motor
Configuration Switch
See Pump Sizing section under
the appropriate controller model
for proper configuration setting.
Bl
k
Br
w
G
ry
(O
ut
pu
t)
Mounting Screw Location
Mounting Screw Location
Motor Cable*
Power Supply from Circuit Breaker*
Mounting Screw Location
Franklin Electric Motor
Pump
(Discharge into drain rated for max pump
output at relief pressure)
Pressure Gauge
Pressure Sensor
Pressure Relief Valve
Drain V
alve
(T
o Residence)
Tank Precharge Inflation V
alve
Pressure
Tank
See
Table 4 (on Page 14) for recommended minimum tank size.
SubDrive75/100/150 Controller
Pressure
Sensor Cable
(included)
* Note:
To avoid possible interference with other appliances,
please refer to the Installation Guide and observe all precautions regarding power cable routing.
Submersible pumps can develop very high pressure in some situations. Always install a pressure relief valve able to pass full pump flow at 6.8 bar
.
Install the pressure relief valve near the pressure tank.
DANGER
The tank and pressure sensor should remain on same elevation within 2 m to prevent over pressure of tank.
The Safety earth ground connections are marked at their terminals using the “ ” symbol.
INFO
INFO
Quick Reference Guide to Controller Installation SubDrive75/100/150
13
Technical changes without notice / Techn. Änderungen vorbehalten / Modifications techniques réservées sans préavis / 5930