OPERATION TESTING

Testing Automatic Pump Operation

7

If the unit is going to be idle for a period of time, follow the cleaning instructions outlined in 

“Cleaning 

Impeller and Volute” on page 9

Do not let the unit freeze. This may cause cracking or distortion that may 

destroy the unit.

Testing Automatic Pump Operation

The 9EC-CIA-SFS, 9ECH-CIA-SFS, and 10ECH-CIA-SFS automatic pumps are equipped with an integral float-
operated mechanical switch. Automatic operation is achieved through the pump cord. 
The 9EC-CIA-RF, 9EC-CIA-RF, and 10ECH-CIA-RF pumps have automatic switches with piggyback plugs on 
the switch cords. The pump must be plugged into piggyback switch cord for automatic operation.
When these pumps are installed in a basin with a sealed cover, switch operation cannot be observed. The 
basin cover will usually have a spare hole that is plugged with a rubber plug. This plug can be removed and 
switch operation can be observed. To test system operation, follow these steps:
1.

Plug the power cord into a grounded receptacle with voltage consistent with the pump voltage, as indi

-

cated on the pump nameplate.

2. Be sure the gate valve in the discharge line is open.
3. Run water into the basin until the pump is activated. Do not attempt to run the pump without water; 

this could result in permanent damage to the pump.

4. Confirm that the pump and its float switch are functioning as intended.
5. Confirm that the ON/OFF levels are within specification, and confirm that no potential obstructions 

exist that could inhibit switch operation.

6. Confirm that there are no leaks in the pump discharge plumbing and main home drain pipe plumbing.

NOTE

: It is normal for a stream of water to spray from the air bleed hole in the pump's plumbing. Con

-

firm that this spray is captured within the basin.

7. Allow the pump to operate through several on/off cycles.

Testing the Float Switch

A float switch can be bench tested by using an ohmmeter to check for continuity between the incoming and 
outgoing connections of the piggyback plug while raising and lowering the float.

Содержание Little GIANT 10ECH Series

Страница 1: ...FETY INSTRUCTIONS 2 INTRODUCTION 3 Product Description 3 Specifications 3 INSTALLATION 4 Physical Installation 4 Electrical Connections 6 OPERATION TESTING 6 Testing Automatic Pump Operation 7 Testing...

Страница 2: ...lyzer to ensure power neutral and ground wires are properly connected If not a qual ified licensed electrician should correct the problem Wire pump system for correct voltages The pump has been evalua...

Страница 3: ...printed copy Please examine your item s carefully to ensure that no damage occurred during shipment If damage has occurred please contact the place of purchase They will assist you in replacement or r...

Страница 4: ...nd piping while assembling and when installed Failure to do so may cause the piping to break the pump to fail motor bearing failures etc Always install a union in the discharge line just above the bas...

Страница 5: ...Typical Installation 1 2 3 4 5 6 7 8 9 10 11 12 1 Gate Valve 4 Switch Power 7 Discharge 10 Caulking Hub 2 Check Valve 5 Pump Power 8 Gas Tight Basin 11 3 16 Air Bleed Hole 3 Union 6 Vent 9 Intake 12...

Страница 6: ...mp is allowed to run dry Pump should be totally submerged for proper cooling of the motor when pump is operated for extended periods Pump HP Voltage VAC Breaker Amps 9EC 4 10 115 15 9ECH 4 10 115 15 1...

Страница 7: ...served To test system operation follow these steps 1 Plug the power cord into a grounded receptacle with voltage consistent with the pump voltage as indi cated on the pump nameplate 2 Be sure the gate...

Страница 8: ...to the pump Do not overfill the basin or test reservoir 6 If the pump is provided with an attachment plug on the power cord plug the pump s power cord into a ground fault circuit interrupter GFCI rec...

Страница 9: ...from the air bleed hole If not clear the hole of any deposits or debris Cleaning Impeller and Volute Periodic cleaning of the pump parts will prolong the life and efficiency of the pump Refer to the a...

Страница 10: ...e check valve and inspect for proper operation Lift too high for pump Check rated pump performance Inlet to impeller plugged Pull pump and clean Pump is air locked Remove pump and clean air bleed hole...

Страница 11: ...Parts Number Part Number Description 1 599210 599121 599209 RF Series Piggyback Float Switch 115 V 20 FT Cord RF Series Piggyback Float Switch 115 V 30 FT Cord RF Series Piggyback Float Switch 230 V 2...

Страница 12: ...Franklin Electric Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com For technical assistance please contact Form 998781 Rev 000 11 19...

Страница 13: ...RIDAD 2 INTRODUCCI N 3 Descripci n del producto 3 Especificaciones 3 INSTALLACI N 4 Instalaci n fisica 4 Instalaci n t pica 5 Conexiones el ctricass 6 PRUEBA DE OPERACI N 6 Pruebas de funcionamiento d...

Страница 14: ...con conexi n a tierra Para reducir el riesgo de descarga el ctrica aseg rese que se conecte solo a un recept culo del tipo con conexi n a tierra que est conectado apropiadamente a tierra La tercer pun...

Страница 15: ...egiant com o bien llame al departamento de Soporte t cnico para obtener una copia impresa Examine su bomba en forma minuciosa para asegurarse de que no haya sufrido da os durante el env o Si sufri da...

Страница 16: ...liza la tuber a se puede romper la bomba puede tener fallas los cojinetes del motor pueden tener fallas etc Siempre instale una uni n en la l nea de descarga justo por encima de la cubierta del recipi...

Страница 17: ...ador enchufe de ali mentaci n 7 Descarga 10 Cubo de calafateo 2 V lvula de retenci n 5 Enchufe de ali mentaci n de la bomba 8 Dep sitoimpermeable a los gases 11 Orificio de purga de aire de 3 16 pulg...

Страница 18: ...da para estar refrigerada mediante el bombeo de l quido Si la bomba funciona en seco es posible que da e el sello y que el motor falle Las bombas est n equipadas con un interruptor de flotador atado o...

Страница 19: ...ptor se puede observar Para probar la operaci n del sistema siga estos pasos 1 Conecte la bomba a un suministro de energ a adecuado que tenga un voltaje congruente con el voltaje de la bomba como se i...

Страница 20: ...eta ni el dep sito de prueba 6 Si la bomba viene con un enchufe de seguridad en el cable de alimentaci n enchufe el cable de alimentaci n de la bomba a un recept culo con un interruptor de circuito po...

Страница 21: ...itos o residuos Limpiar el impulsor y la voluta Al limpiar peri dicamente las piezas de la bomba se prolongar la vida til y la eficiencia de la bomba Consulte el ensamblaje y el desmontaje del cabezal...

Страница 22: ...ara comprobar que funcione bien Elevaci n demasiado alta para la bomba Revise el desempe o nominal de la bomba Entrada al impulsor obstruido Quite la bomba y l mpiela La bomba est obturada por aire Si...

Страница 23: ...mero de parte Descripci n 1 599210 599121 599209 RF Flotante Remoto 115 V Cable de alimentaci n de 20 pies RF Flotante Remoto 115 V Cable de alimentaci n de 30 pies RF Flotante Remoto 230 V Cable de...

Страница 24: ...Franklin Electric Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com For technical assistance please contact Form 998781 Rev 000 11 19...

Страница 25: ...ES DE S CURIT 2 INTRODUCTION 3 Description du produit 3 Sp cifications 3 INSTALLATION 4 Installation physique 4 Installation typique 5 Branchements lectriques 6 TEST DE FONCTIONNEMENT 6 Test de Foncti...

Страница 26: ...ache de mise la terre Pour r duire le risque de d charge lectrique assurez vous de seulement brancher la pompe une prise lec trique correctement mise la terre Ne retirez pas la troisi me branche de la...

Страница 27: ...ements complets sur la garantie consulter le site www littlegiant com ou communiquer avec le soutien technique pour en obtenir une copie imprim e Examiner soigneusement la pompe pour s assurer qu elle...

Страница 28: ...entra ner la rupture des tuyaux la d faillance de la pompe la d faillance des paliers du moteur etc Installez toujours un raccord union dans le conduit de refoulement juste au dessus du couvercle de b...

Страница 29: ...11 12 1 Clapet de la vanne 4 Corde de pouvoir de Changement de Flotteur 7 Tuyau de sortie 10 Collet d tanch it Orifice de prise d air 2 Clapet de retenue 5 Corde de pouvoir de pompe 8 Bassin tanche au...

Страница 30: ...tilis e pendant une certaine p riode suivez les instructions de nettoyage pr sent es dans la prochaine section Ne laissez pas l unit geler Cela peut causer des fissures ou des distorsions qui peuvent...

Страница 31: ...absence de toute fuite dans la plomberie de refoulement de la pompe et dans le tuyau de drainage principal de la maison REMARQUE Il est normal qu un filet d eau s chappe de l orifice de prise d air d...

Страница 32: ...cle de l orifice d un boulon situ la base de l appareil Assurez vous que ce filet est recueilli l int rieur du bassin 8 Si la pompe ne fonctionne pas comme pr vu d branchez le cordon d alimentation de...

Страница 33: ...u remplacez les composants touch s 4 Confirmez que les colliers de serrage de tous les raccords flexibles sont correctement fix s et bien serr s 5 Testez le fonctionnement du syst me Se r f rer TEST D...

Страница 34: ...vation est trop lev e pour la pompe V rifiez le tableau des valeurs nominales L aspiration vers l impulseur est obstru e Retirez la pompe et nettoyez la La pompe est bloqu e par de l air Enlever la po...

Страница 35: ...e Description de pi ce 1 599210 599121 599209 RF Flotteur Distance 115 V Cordon d alimentation de 20 pieds RF Flotteur Distance 115 V Cordon d alimentation de 30 pieds RF Flotteur Distance 230 V Cordo...

Страница 36: ...Franklin Electric Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com Pour l aide technique entrez s il vous pla t en contact Form 998781 R v 000 11 19...

Отзывы: