5

THE INSTALLATION PROCEDURE

Install the Franke Omni 4in1 kitchen tap

Carrying out this operation first will make it easier to plan  
the layout inside the cabinet. For safety, it is advisable to 
locate the tap at, or towards, the back of the sink out of  
reach of smaller children.

1.  The tap will require a standard 35mm diameter hole 

drilled in the kitchen work surface. 

Important note: 

before drilling the hole make sure that there is enough 
clearance between the tap handles and the back splash 
when the handles are in the fully open position.

2.  Insert the flexible hoses and the wire lead through the 

35mm hole. 
 
Position the tap for the owners convenience. (The tap  
can be rotated 180° for left handed operation of the 
boiling water function).

3.  Working inside the cabinet, slide the gasket (8) and the 

clamp plate (5) over the hoses and the two studs at the 
base of the tap. Screw the two clamp nuts (6) on to the 
studs using the box spanner (7).

4.  Check the alignment of the tap then tighten the two 

clamp nuts using the box spanner to firmly secure it on 
the work surface.

Plan the layout inside the cabinet

•  Determine the best positions for the hot and cold mains 

water supply.

•  Determine the best positions for the boiler and the filter 

unit, making sure that the boiler power cable, the flexible 
hoses, and the filter cartridge change indicator cable, are 
all within comfortable reach of their respective 
connection points without them being compressed, 
stretched or kinked.

•  The boiler must be installed upright with the hose 

connections at the top, never on its side.

•  Allow a minimum clearance of 80mm at the top of the 

boiler for the connecting hoses.

•  Choose a location for the filter unit (21) and the stop 

valve (23) to allow convenient access for future filter 
cartridge changes.

SCALE 1 : 2

240mm

  Min

100mm

235mm

385mm

35mm

60mm Max

Содержание OMNI 4in1

Страница 1: ...2 FRANKE OMNI 4in1 BOILING WATER SYSTEM Installation instructions...

Страница 2: ...be between minimum 1 5 BAR 22 psi maximum 5 BAR 73psi Introduction This guide explains how to install a new Franke Omni 4in1 Boiling Water System Thank you for purchasing a Franke Omni Tap System In k...

Страница 3: ...member Boiling water is potentially dangerous and great care should be exercised when using the Franke Omni tap The installation must be carried out by a suitably qualified professional in strict acco...

Страница 4: ...t elbow 14 Tapered silicone washer for boiling water outlet red sticker 15 Flat silicone sasher for boiler water inlet green sticker 16 Vent assembly 17 Saddle clamp 18 Vent hose 19 Vent assembly elbo...

Страница 5: ...over the hoses and the two studs at the base of the tap Screw the two clamp nuts 6 on to the studs using the box spanner 7 4 Check the alignment of the tap then tighten the two clamp nuts using the b...

Страница 6: ...ing to eventual failure 1 Position the filter unit 21 vertically with the hoses at the top in its previously determined location 2 Mark the positions for the two filter unit support screws 24 using th...

Страница 7: ...two black rubber inserts for 41mm waste pipe Leave them in place for 32mm pipe 3 Place the saddle clamp in position on the chosen section of waste pipe and re assemble the clamp Tighten the nuts and b...

Страница 8: ...he nut firmly sufficient to make a watertight seal Do not overtighten 5 Take the push fit elbow 13 Connect the elbow to the grey push fit stem on the end of the vent flexible hose 18 black indicator P...

Страница 9: ...er is discharging from the vent pipe Important note If water does not start to discharge from the vent pipe into the cup after 10 minutes switch off the power operate the boiling water function on the...

Страница 10: ...Omni tap The Omni tap is manufactured in stainless steel and is therefore extremely durable and stain resistant All that is required to keep it in good condition is a regular wipe over with a damp clo...

Страница 11: ...rtridge for the Franke Omni system is the Franke 08 The Franke 08 will remove sediment chlorine and other chemicals as well as prevent limescale from damaging the boiler It should be replaced every 6...

Страница 12: ...issue check the water pressure using a gauge rather than estimating to ensue a reliable reading As previously stated it should fall between 1 5 bar 22 psi 5 bar 73psi If the problem persists remove t...

Страница 13: ...bags will often remedy the problem Alternatively you can consider switching to a Franke 06 cartridge which will remove the calcium and magnesium however please note this filter will need to be change...

Страница 14: ...air or replacement of a product that has failed for any of the following reasons Faulty installation repairs or alterations not in accordance with the installation guide Normal wear and tear Accidenta...

Страница 15: ...electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by ina...

Страница 16: ...l Street Cawston Norfolk NR10 4FE Phone 44 0 1603 875 468 Email info frankefilterflow com Franke UK Limited West Park MIOC Styal Road Manchester M22 5WB Phone 44 0 161 436 6280 Fax 44 0 161 436 2180 E...

Отзывы: