USE

 

 
 
 

Control panel 

Button 

Function Display 

A 

Carriage Closed: Press for approx. 1.5 Seconds to open 
the carriage, turn the lights on, turn the Fans on and start 
the Motor at the last speed set. 
Carriage Open: Press briefly to turn the Motor off or to 
start it at the last speed set. Press for 1.5 seconds to turn 
the Motor and the Fans off and to close the carriage. 

Displays the set speed. 
 
With the Fans on, the Display on the left shows 
an animation. 
 

B 

Press briefly to decrease the working speed. 
Press for 2 Seconds to turn the Fans off. 
Once the Fans are turned off  they will turn on automati-
cally every time the Carriage is extracted, or when the 
Working speed is increased. 

C 

Increase the working speed. 

D 

Intensive function: 
Can only be activated with the Carriage open at any 
speed and with the Motor turned off. It has a timer set to 
10 minutes, after which the system will return to the 
speed set before. Suitable to deal with maximum levels 
of cooking fumes. 
When the function is enabled/disabled, the Fans are en-
abled/disabled. 
Cannot be enabled when Delay or 24H are on. 

 
Displays HI and the time remaining, alternately. 
 
It is disabled by pressing the Button or turning 
the Motor off. 

E 

24H function: 
Carriage Closed: The function is enabled and the carriage 
remains closed. 
Carriage Open: When the function is enabled the Motor 
and the Fans turn off and the carriage returns; After this 
the 24H function starts. 
Starts the Motor at a speed that allows suction of 100 
m3/h for 10 minutes per hour for 24h, after which the 
Motor will stop. 
When the filter alarm is active, press the button for ap-
proximately 4 seconds with the Motor and Lights off to 
reset the alarm. Reset is indicated by the fact that the 
Display turns off. 
These signals are only visible when the Motor is off. 

 
Displays  24, and the dot on the Right flashes 
once a second when the Motor is on, while 
when the Motor is off only 24 appears. 
 
 
It is disabled by pressing the Button or turning 
the Motor off. 
 
 
When the procedure terminates, the indication 
shown previously turns off: 
FF indicates the need to wash the metal grease 
filters. The alarm is triggered after the Hood has 
been in operation for 100 working hours.  
EF indicates the need to change the activated 
charcoal filters, and to wash the metal grease 
filters. The alarm is triggered after the Hood has 
been in operation for 200 working hours. 

F 

Delay function: 
Enables automatic shutdown of the Motor, the Fans and 
the Lighting with a 30’ delay. 
Cannot be enabled when Intensive or 24H are on. 

 
Displays the speed of the Motor and the time 
remaining, alternately. 
It is disabled by pressing the Button or turning 
the Motor off. 

G 

Turns the lighting system on and off. 
Press for 2 Seconds to allow an optional additional appli-
ance to be turned on and off. 

  

H 

Turns the reduced intensity lighting system on and off. 

 

Warning: Never rest anything on the sliding carriage when it is open! 

 

Содержание FNES 907 BTH XS/GLASS

Страница 1: ...lation Cooker Hood Istruzioni per l uso e l installazione Cappa Mode d emploi et installation Hotte de Cuisine Bedienungsanleitung und Einrichtung Dunstabzugshaube Kullan m ve montaj talimatlar Davlum...

Страница 2: ...EN 2 2 Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS 7 CHARACTERISTICS 8 INSTALLATION 9 USE 12 MAINTENANCE 13...

Страница 3: ...naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be contin...

Страница 4: ...2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 7 3...

Страница 5: ...per chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical r...

Страница 6: ...staller To install a 120 mm air exhaust connection insert the re ducer flange 9 on the hood body outlet Fix the pipe in position using sufficient pipe clamps not sup plied Remove any activated charcoa...

Страница 7: ...widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c 2 9 x 9 5 supplied Make sure...

Страница 8: ...he Fans turn off and the carriage returns After this the 24H function starts Starts the Motor at a speed that allows suction of 100 m3 h for 10 minutes per hour for 24h after which the Motor will stop...

Страница 9: ...and need to be cleaned whenever the FF sign appears on the display or at least once every 2 months use or more frequently if use is particularly intensive Resetting the alarm signal Turn the Lights a...

Страница 10: ...ter saturation alarm DEACTIVATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Turn the Lights and the Suction motor off then disable the 24h func tion if enabled Press button E un...

Страница 11: ...436004063_ver2 Franke S p a Via Pignolini 2 37019 Peschiera del Garda VR www franke it...

Отзывы: