Charcoal filter (recycling version) 

•  This filter cannot be washed or regenerated. It must be replaced when the EF appears on the 

display or at least once every 4 months.  

Activation of the alarm signal  
•  In the recycling version hoods the filter saturation alarm must be activated during the instal-

lation or later. 

•  Switch off the hood and the lights. 
•  Disconnect the hood from the mains supply. 
•  When restoring the connection press and hold B-key. 
•  When releasing the key two rotating rectangles appear on the display. 
•  Within 3 seconds press the B-key until a flashing confirmation appears on the dispaly: 
  •  2 flashes with EF - charcoal filter saturation alarm ACTIVATED 
  •  1 flash with EF - charcoal filter saturation alarm DEACTIVATED.  

 

CHANGING THE ACTIVATED CHARCOAL FILTER 

Resetting the alarm signal 
•  Turn the Lights and the Suction motor off, then disable the 24h func-

tion, if enabled. 

•  Press button E until the display turns off. 
Changing the Filter 
•  Open the Comfort Panel by turning the knobs. 
•  Remove the Metal grease filters. 
•  Remove the saturated Activated charcoal filter, using the hooks pro-

vided. 

•  Fit the new Filter, hooking it into place. 
•  Replace the Metal grease filters. 
•  Close the Comfort Panel by turning the knobs. 

 

 

Lighting 

LIGHT REPLACEMENT 

20 W halogen light. 
•  Remove the snap-on lamp cover by levering it from under the 

metal ring, supporting it with one hand. 

•  Remove the halogen lamp from the lamp holder by pulling 

gently. 

•  Replace the lamp with a new one of the same type, making 

sure that you insert the two pins properly into the housings on 
the lamp holder. 

•  Replace the snap-on lamp cover.

 

 

 

Содержание FNES 907 BTH XS/GLASS

Страница 1: ...lation Cooker Hood Istruzioni per l uso e l installazione Cappa Mode d emploi et installation Hotte de Cuisine Bedienungsanleitung und Einrichtung Dunstabzugshaube Kullan m ve montaj talimatlar Davlum...

Страница 2: ...EN 2 2 Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS 7 CHARACTERISTICS 8 INSTALLATION 9 USE 12 MAINTENANCE 13...

Страница 3: ...naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be contin...

Страница 4: ...2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 7 3...

Страница 5: ...per chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical r...

Страница 6: ...staller To install a 120 mm air exhaust connection insert the re ducer flange 9 on the hood body outlet Fix the pipe in position using sufficient pipe clamps not sup plied Remove any activated charcoa...

Страница 7: ...widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c 2 9 x 9 5 supplied Make sure...

Страница 8: ...he Fans turn off and the carriage returns After this the 24H function starts Starts the Motor at a speed that allows suction of 100 m3 h for 10 minutes per hour for 24h after which the Motor will stop...

Страница 9: ...and need to be cleaned whenever the FF sign appears on the display or at least once every 2 months use or more frequently if use is particularly intensive Resetting the alarm signal Turn the Lights a...

Страница 10: ...ter saturation alarm DEACTIVATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Turn the Lights and the Suction motor off then disable the 24h func tion if enabled Press button E un...

Страница 11: ...436004063_ver2 Franke S p a Via Pignolini 2 37019 Peschiera del Garda VR www franke it...

Отзывы: