Franke FNES 907 BTH XS/GLASS Скачать руководство пользователя страница 9

 

 

 

 

EN 

 

1
3

 

13 

MAINTENANCE

 

Cleaning the Comfort Panel 

•  Open the Comfort Panel by turning the knobs. 
•  Unfasten the panel from the hood canopy by sliding the fixing 

pin lever provided. 

•  The comfort panel must never be washed in the dishwasher. 
•  Clean the outside with a damp cloth and neutral detergent. 
•  Clean the inside using a damp cloth and neutral detergent; do 

not use wet cloths or sponges, or jets of water; do not use abra-
sive substances. 

•  On completing the operation, hook the panel up to the hood 

canopy again and close it by turning the knobs in the opposite 
direction. 

 

Metal grease filters 

These can be washed in the dishwasher, and need to be cleaned whenever 
the FF sign appears on the display or at least once every 2 months use, or 
more frequently if use is particularly intensive.  

Resetting the alarm signal 
•  Turn the Lights and the Suction motor off, then disable the 24h func-

tion, if enabled. 

•  Press button E until the display turns off. 

Cleaning the Filters 
•  Open the Comfort Panel by turning the knobs. 
•  Remove the Filters one at a time, pushing them towards the back of the 

unit and at the same time pulling downward. 

•  Wash the Filters without bending them, and leave them to dry com-

pletely before replacing. (If the surface of the filter changes colour as 
time goes by, this will have absolutely no effect on the efficiency of 
the filter itself.)  

•  Replace, taking care to ensure that the handle faces forwards. 
•  Close the Comfort Panel by turning the knobs. 

 

Содержание FNES 907 BTH XS/GLASS

Страница 1: ...lation Cooker Hood Istruzioni per l uso e l installazione Cappa Mode d emploi et installation Hotte de Cuisine Bedienungsanleitung und Einrichtung Dunstabzugshaube Kullan m ve montaj talimatlar Davlum...

Страница 2: ...EN 2 2 Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS 7 CHARACTERISTICS 8 INSTALLATION 9 USE 12 MAINTENANCE 13...

Страница 3: ...naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be contin...

Страница 4: ...2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 7 3...

Страница 5: ...per chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical r...

Страница 6: ...staller To install a 120 mm air exhaust connection insert the re ducer flange 9 on the hood body outlet Fix the pipe in position using sufficient pipe clamps not sup plied Remove any activated charcoa...

Страница 7: ...widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c 2 9 x 9 5 supplied Make sure...

Страница 8: ...he Fans turn off and the carriage returns After this the 24H function starts Starts the Motor at a speed that allows suction of 100 m3 h for 10 minutes per hour for 24h after which the Motor will stop...

Страница 9: ...and need to be cleaned whenever the FF sign appears on the display or at least once every 2 months use or more frequently if use is particularly intensive Resetting the alarm signal Turn the Lights a...

Страница 10: ...ter saturation alarm DEACTIVATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Turn the Lights and the Suction motor off then disable the 24h func tion if enabled Press button E un...

Страница 11: ...436004063_ver2 Franke S p a Via Pignolini 2 37019 Peschiera del Garda VR www franke it...

Отзывы: