background image

www.schweigen.com.au

RANGEHOOD & INSTALLATION GUIDE

WINU-6

Revision V2

  01/10/21

Summary of Contents for WINU-6

Page 1: ...www schweigen com au RANGEHOOD INSTALLATION GUIDE WINU 6 Revision V2 01 10 21...

Page 2: ...lation 12 Rangehood Size vs Cooktop Size 12 Overhead cabinet Rangehood Installation position 12 Mounting Instructions 13 Recommended Installation Height for Induction Cooktop 13 Mounting Points for Bo...

Page 3: ...website www schweigen com au This appliance and its packaging are produced by processes that minimise waste and respect the environment Please help us to continue this effort to protect the environmen...

Page 4: ...including children with reduced physical sensory or mental capabilities or lack of experience and or knowledge Unless the person has been given supervision or instruction concerning the use of the ap...

Page 5: ...e by a qualified technician and that the indicated instructions and local regulations in force are met using materials that are compliant with the applicable legislation 11 The company will not be res...

Page 6: ...use always ensure that all controls are in the OFF position When frying with a gas flame take particular care not to allow the oil or grease in the pan to catch fire Flamb Electrical Cord Ensure the...

Page 7: ...vary from model to model 1 2 3 4 5 491mm approx 271mm approx Note Please make sure that all plastic protection on the rangehood and filters are removed before use Dimensions may be subject to change...

Page 8: ...ow speed setting Medium speed setting High speed setting Turn on off the lamp Speed Control This undermount is equipped with a 3 speed mechanical control Speed control usage suggestions Low speed for...

Page 9: ...y important for the liquid soap to not contain granules that could scratch the surface First apply the solution to a soft cloth and then rub the cloth over the rangehood It is important to follow the...

Page 10: ...days depending on use The bafles can be washed by hand or in the dishwasher Washing by hand Immerse the filter in hot water and a suitable detergent and when clean rinse with plenty of hot water Dishw...

Page 11: ...tain heat for a short period of time after being switched off Replacing the Light Bulb Step 2 Gently turn light bulb clockwise pull the light bulb down and remove it from the light holder Step 3 Inser...

Page 12: ...benchtop and overhead cabinetry depth before installing the rangehood The information below is to be used as a guide only drawings are not to scale and do not account for all circumstances The cooktop...

Page 13: ...articular to cooking with an induction cooktop Schweigen recommends a height between 700 750mm Refer to page 20 for further information IMPORTANT If the user decides to install the rangehood at a dist...

Page 14: ...ase make sure all plastic protection on the rangehood and filters are removed before use DANGER Always switch off and disconnect the power supply before installing the rangehood Failure to do so may c...

Page 15: ...installed from the bottom of the rangehood into the cabinet Step 3 Connect the 6 pin connector on the face plate to the rangehood before securing the face plate to the cabinet using provided screws I...

Page 16: ...e efficient and stronger Back Draft Fins For applicable models The supplied ducting has been manufactured with an allowance for the back draft fins to operate without hindrance It is the smooth extend...

Page 17: ...tivated carbon filter into the unit and turn it in a clockwise direction Repeat the same on the other side Please ensure that the filter is securely locked otherwise it can come loose and become a haz...

Page 18: ...city Keep the curves or bends to a minimum If they do exist try to keep the angles as open as possible Straight ducting is the most effective installation Never fit reductions next to curves or bends...

Page 19: ...ducting 3 Connect flexible ducting to the outlet on rangehood using a ring clamp Please DO NOT rip the ducting 4 Main Power Lead Male Plug Maximum of 4 metres of ducting for best result NOTE Rangehood...

Page 20: ...istance from cooktop to the rangehood Speed of food liquid heating Filter size larger canopy preferred Quality of pots or cookware you are using high quality recommended How to reduce the possibility...

Page 21: ...ase ensure that there is power to the rangehood and the rangehood is switched on Check lamp switch Lamp switch should be at on position Check metal filter Metal filter should be washed regularly see f...

Page 22: ...e appliance at their expense Service Lodging an Online Service Request In the event that the failure is not due to the faults mentioned in the Troubleshooting section you can lodge an online Service R...

Page 23: ...3 9 Specifications Front Dimensions Technical Specifications Model WINU 6 Feeding Voltage 240V 50Hz Lamp Power LED W 2 x 1 5W supplied Lamp Power Halogen W 2 x 35W optional 295 265 525 485 76 265 150...

Page 24: ...for their purpose s prior to use In no event will Schweigen Home Appliances be responsible for damages of any nature whatsoever resulting from the use of or reliance upon information from their websi...

Page 25: ..._n_ _RH Section_ Page 25 Notes...

Page 26: ..._n_ _LH Section_ Page 26 Notes...

Page 27: ...Page 27 Notes...

Page 28: ...rive Dingley Village Victoria 3172 Phone 1300 881 693 Email sales schweigen com au Web www schweigen com au New Zealand 5 Tolich Place Henderson Auckland 0610 Phone 0800 200 510 Email info parex emers...

Reviews: