10
ZMI
_001_
2000
1000
69-A
Q
RM312
_#SE
N
_#AQ
U
_#V3
21. Fault Correction
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
22. Replacement Parts
Fault
Cause
Remedy
Water does not flow
– Stop valve is closed
➯
Open it
– Functional part faulty
➯
Replace it
Water flows conti-
nuously
– Functional part faulty
➯
Replace it
– Aerator calcified
➯
Clean it
Water flow too weak
– Aerator calcified
➯
Clean it
– Supply pressure too low
➯
Check it
– Grit filter/Non-return valve dirty
➯
Clean it
– Water flow regulator not fully
opened
➯
Open it
Flow duration too
short or too long
– Incorrect setting
➯
Adjust it
– Grit filter is clogged
➯
Clean it
– Aerator/shower head clogged with
dirt
➯
Clean it
– Functional part/upper section faulty
➯
Replace it
Water is too hot
– Temperature limit is incorrectly set
or not set at all
➯
Adjust it
– Cold water is turned off
➯
Open it
– Grit filter/Non-return valve in the
cold-water connection is faulty
➯
Replace it
Water is too cold
– Grit filter/Non-return valve in the
hot-water connection is faulty
➯
Replace it
– Hot water is turned off
➯
Open it
Bezeichnung
Best.-Nr.
1 Push-cap handle . . . . . . . . . . . . . . 2000104775
2 Functional part . . . . . . . . . . . . . . . . 2000104372
3 Stop ring. . . . . . . . . . . . . . . . . . . . . 2000104837
4 Installation kit comprising:
O-rings
Non-return valves
Grit filters . . . . . . . . . . . . . . . . . 2000105492
5 Aerator (PU with 10 pcs.). . . . . . . . 2000104691
Zubehör
Best.-Nr.
Theft-resistant aerator
with flow-rate regulator
6 l/min . . . . . . . . . . . . . . . . . . . 2000101160
Special wrench for theft-resistant
aerator . . . . . . . . . . . . . . . . . . . 2000105960
1 Replacement kit for functional part
Rubber parts
Pressure spring
Circlip
Sealing plug
Grub screw. . . . . . . . . . . . . . . . . . 2000104785