Warning!
Use the fitting only with the non-return valves and the grit filters specified.
Failure to observe can result in an increased bacterial load in drinking water and
cause a health risk or even risk of death.
☞
Important!
Before installing, flush the pipes in compliance with DIN 1988.
10.1
Apply sealing material to the S-connectors (a) and screw them in.
☞
Apply grease to the O-rings on the S-connectors!
10.2
Place the wall plate (b) over the S-connectors, align it, and then secure it with the
nuts (c).
10.3
Slide the flange (d) on to the wall plate and secure it with the washer (e) and the
screw (f).
10.4
Insert the grit filters (g).
10.5
Screw in the faucet screw (h) until it protrudes 16 mm and the borehole is vertical.
☞
Apply grease to the O-rings on the guide bushing!
10.6
Insert the guide bushings (i).
Minimum flow pressure:
1.0 bar
Recommended flow pressure:
1-5 bar
Maximum operating pressure:
10 bar
Calculation flow rate:
0,07 l/s
0,07 l/s
Volumetric flow:
0.10 l/s at a flow pressure of 3 bar
Flow duration at 38 °C:
1-15 s adjustable
Quantity
Description
1
AQUAMIX self-closing single mixer
1
Installation and Operating Instructions