Installation Instructions
& User Guide
Prior to Installation
Please leave these instructions
with the end user
All products manufactured and supplied by Bristan are safe to use
provided that they are installed, operated and receive regular
maintenance in accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999
and current by-laws. For full Installation Requirements & Notes (IRN)
please visit
wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease
of future maintenance. Before installing this product the water supply
must be thoroughly flushed in order to remove any swarf, solder etc.
Full access must be made available for future maintenance/
servicing purposes.
Before drilling into walls, check that there are no hidden electrical
wires, cables or water supply pipes. This can be checked with the
aid of an electronic detector.
If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
This product must not be modified in any way
as this will invalidate the guarantee.
If in doubt, contact a registered plumber, your Local Water
Authority or the Secretary of the Institute of Plumbing,
address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
6
Attach the fixed head.
To adjust height of head, slide the riser
to desired height (see step 2).
3
1
Rotate the
shroud until
the opening
aligns with the
isolation screw.
Remove the
concealing cap
from the shroud.
2
5
Identify the
required position of
the valve and prepare
the water supply pipes.
Supply pipes should be
150mm apart.
Using the backplate
supplied with the
wallmount, mark and
drill holes.
Secure the isolator
onto the backplate
ensuring the olive is
positioned over the
pipework correctly.
Push shrouds to the back
of the wall outlet, securing
them against the rubber
fixing plate
4
3
1
Installation
150mm C
entr
es
1
Isolation
2
Secure the rubber backplate
and backplate into place.
Insert filter washer and
secure the shower to
the wall mount.
21mm
21mm
REMEMBER
hot on the left,
cold on the
right
To reduce the build up of limescale
and to ensure this shower works to
its maximum performance we
recommend this shower is serviced
every 6-12 months depending on the
hardness of your water.
Servicing Intervals
Turn the screw to isolate the water.
Reverse the process when turning
the water back on.
4
5
Riser Installation
2
Product Code: BUZ2 SHXDIVCTFF C (D4)
IMPORTANT
Pack Contents
150mm
Centres
1.0
5.0
Pressure
BAR
0.2
4.0
2.0 3.0
Pressure
BAR
1.0
5.0
0.2
4.0
2.0
3.0
60°C
65°C
Specifications
Maximum Static Pressure:
10.0 bar
Inlet Water Temperature
Inlet Connections
Min:
1.0 bar
Max:
5.0 bar
Working Pressures
The inlet hot water must
be at least 10°C above the
required blend temperature.
Factory pre-set
38°C
Inlet Dimensions
5°C
25°C
Cold Water Supply
Min:
5°C
Max:
25°C
Hot Water Supply
Tools You’ll Need
60-65°C Recommended
x1
x2
x2
x2
x2
x8
x8
x2
x2
x2
x2
x1
x1
x2
x1
x1
x1
x1
x1
x1
x1
x1
Flat Head Screwdriver
Cross Head Screwdriver
Hexagonal Keys
Pipe Cutter
Drill
Spanner
Safety Glasses
Detector
Using a spirit level
to ensure the
riser is positioned
correctly, use
the assembled
riser to mark the
desired position
of the bracket.
Secure the
bracket to
the wall.
Secure the riser
bracket and riser
rail.
Slide the
bracket onto the
riser rail, then
push the riser
extension into
the riser rail.
Press & hold
knob on the
bracket to slide
up or down.
Tighten nut to
secure riser.
To adjust the
height unscrew
the nut and
move the pole
to the desired
height. Tighten
nut again to
secure in place.
1/2”
Compression