FPI P36-3 Zero Clearance Direct Vent Gas Fireplace
43
OPERATING
INSTRUCTIONS
1) Read and understand these instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the door frame is
properly positioned. Never operate the ap-
pliance with the glass removed.
5) Verify that the venting and cap are unob-
structed.
6) Ensure that the brick panels are installed.
7) Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have
been incorrectly positioned.
8) The unit should never be turned off, and
on again without a
minimum of a
60
second
wait.
INSTALLING THE
OPTIONAL FAN
120 Volt AC power is needed for the fan switch
and blower. The fan can be hard wired if
desired. The receptacle box should be installed
on the left hand side of the unit by a qualified
electrician. The neutral (wider) slot of the
polarized receptacle should be at the top.
Unit must be grounded at all times. Do not
cut the ground terminal off under any
circumstances.
1) Shut the power off.
2) Remove the standard flush door and the
optional bay door, if installed. Open the
bottom louver door.
3) Loosen the 2 screws holding the Burner
ON/OFF switch and bracket to the bottom
louver and lift the assembly out.
4) Turn the fan base on its side (with the base
facing towards you) and then slide the fan
in towards the rear of the unit. Turn the fan
upright and slip it over the two mounting
studs. Take care not to damage the insula-
tion on the fan base. Ensure that the fan
blades do not rub against the valve
tubing. Diagram 1.
8) Secure the two boxes together with one
screw.
10) Remove the control box
assembly and push the
hold-down clip onto the lou-
ver. Bend the tab until it is at
90
o
to the louver.
12) Secure the fan wires and power cord by
attaching one of the adhesive backed
wire holder clips (Part #910-199) onto the
stove base. Use the second clip to bundle
up the wires approximately 4" from the
control box. Ensure that there is no inter-
ference with the wires when the louver
is closed and that no wire will touch the hot
metal surfaces or sharp edges.
13) Plug the fan power cord into the rear end
of the receptacle box to provide the max-
imum clearance from the louvers.
TO REMOVE THE FAN
1) Shut the power off.
2) Reverse the above instructions.
Note: The bearings are lubricated for
life. Do not lubricate them. Make sure
you vacuum the fan area on a regular
basis.
IMPORTANT:
These fans collect a lot of dust from
within your home. Ensure you maintain
these fan motors on a regular basis by
vacuuming out the fan blades and hous-
ing using a soft brush nozzle.
Diagram 1
Diagram 2
Use the clip & hook on the side of the
control boxes to join them together.
5) Connect fan ground cable to ground lug.
Refer to wiring diagram.
6) Slide the thermodisc/cover assembly into
the bracket clip on the underside of the
firebox. Check that no wire will touch the
hot surfaces. Diagram 2.
7) Attach the Fan control box to the Burner
ON/OFF control box.
Secure the 2 boxes together with one screw.
9) Position the control box assembly on the
bottom louver and mark the position of the
slot on the right side bracket.
Hold control box
assembly in place and
mark the position of the
right side slot
11) Attach the two control boxes to the bottom
louver and tighten the 2 screws on the left
side and 1 screw on the right side.
Secure left
side with 2
screws.
Secure right side with one screw.
OPERATING INSTRUCTIONS
Содержание P36-LP3
Страница 42: ...FPI P36 3 Zero Clearance Direct Vent Gas Fireplace 42 ALTERNATE WIRING DIAGRAM FOR WALL SWITCH INSTALLATION...
Страница 48: ...FPI P36 3 Zero Clearance Direct Vent Gas Fireplace 48 FLUSH BAY DOOR OPTIONS...
Страница 56: ...FPI P36 3 Zero Clearance Direct Vent Gas Fireplace 56 CAST FACEPLATE...
Страница 66: ...FPI P36 3 Zero Clearance Direct Vent Gas Fireplace 66 REPLACEMENT PARTS LIST...