FPI P36-3 Zero Clearance Direct Vent Gas Fireplace
51
REGENCY OPTIONS
FINISHING TRIM
NOTE:
Remove both the Flush Louvers or Bay Louvers and
the Flush Front or Bay Front prior to installing the
Finishing Trim.
1) Install the Finishing Trim sides as shown in the diagram, line
up the holes in the side trim with the holes in the firebox side.
2) Secure with 2 screws per side.
3) Loosen the 3 screws in the top inside edge of the firebox.
4) Slide the Finishing Trim Top over the Side Trim pieces and fit
the bottom bracket slots over the screws. Tighten the 3
screws to secure.
5) Loosen the 2 screws on the hinge bracket on both the left
and right side of the louver.
6) Hook the bottom finishing trim to the side trims and snap in.
7) Tighten the 2 screws on the left and right hinge bracket to
secure.