FPI P36-3 Zero Clearance Direct Vent Gas Fireplace
28
Diagram 1
INSTALLATION
The P36 is approved for a 40 ft. straight vertical, with rigid pipe vent systems
for Propane and Natural Gas, as per the diagram 1.
The shaded area in the diagram 1 shows all allowable combinations of straight
vertical and offset to vertical terminations with rigid pipe vent systems for
Propane and Natural Gas. Maximum two 45
o
elbows allowed.
•
Vent must be supported at offsets.
•
Firestops are required at each floor level and whenever passing
through a wall.
•
Maintain clearances to combustibles.