Part No. 26126 Rev. P September 2019
- 20 -
5000 Series Open Front Cabinets
Setting Up
cont.
REFRIGERATED CABINETS
-
INSTALLATION
Grounding
THIS APPLIANCE MUST BE GROUNDED TO EARTH
The earth lead, in the mains cable, must always be connected to ground.
Terminals are also provided, to allow the cabinet to be bonded to a surge
grounding conductor or to adjacent equipment.
Power Supply
and Earthing
The cabinet is supplied with a three-core mains lead, with phase, neutral and
earth conductors. Before connecting to the power supply, check that the local
supply is correct to that shown on the rating label on the rear of the cabinet.
Electrical
Isolation
An accessible means of isolation must be provided in the electrical supply to the
cabinet.
Condensate
Disposal
On the integral condenser versions, no
drain is required for condensate disposal.
Check that there is no packing material or
debris in the integral condensate boil-off
tray.
The element is automatically controlled,
only operating when water is detected in
the tray.
The condensate must be piped to a drain on the remote condenser versions.
A P-trap must be included in the pipe work, to prevent air entering the bun.
Location
REFRIGERATED CABINETS
-
INSTALLATION
Ventilation
Adequate ventilation must be provided for cooling air to enter and exit through
the rear louvers of the cabinet.
The rear of the cabinet should not be placed close to a wall.
The cooling system is designed to maintain the correct temperature, providing
the rear doors are kept closed and cabinet is not in a draughty location.
Access
Access to the back of the cabinet is also required for loading, cleaning, re-
positioning of shelves and operation of the control panel.
Содержание IN-5C08-OF
Страница 1: ...Refrigerated Open front Cabinets Curved and Square Formats...
Страница 39: ...IN 5C08 12 OF 39 Future Products Group IN 5C08 5C12 OF SQ...
Страница 40: ...Part No 26126 Rev A November 2014 40 5000 Series Open Front Cabinets IN 5C12 OF...
Страница 41: ...IN 5C08 12 OF 41 Future Products Group...
Страница 42: ...Part No 26126 Rev A November 2014 42 5000 Series Open Front Cabinets...
Страница 43: ...IN 5C08 12 OF 43 Future Products Group...