5000 Series Open Front Cabinets
TROUBLE SHOOTING
FAULT
POSSIBLE CAUSE
REMEDY
Cabinet does not operate/start
The mains isolating switch on
the wall, circuit breaker or
fuses are off at the power
board
Turn isolating switch circuit
breaker or fuses on
The power switch on the
cabinet is OFF
Turn the power switch ON
The power switch on the unit is
faulty
Have the switch replaced
HA2 Alarm Display on
Controller
Compressor discharge pipe
high temperature
Turn power off, clean
condenser radiator & pre-filter.
Turn power on.
If no cooling, or alarm returns
within 24 h, call for service.
The cabinet temperature is not
correct
One or more rear doors is
open
Close the doors and re-test
temperature after 30 minutes
Ventilation louvers are blocked Remove blockages
Product is blocking air louvers
Place product on shelves
Evaporator coil fins are
blocked
Remove blockages
Trays are obstructing air flow
Re-position trays on shelves
Thermostat needs adjustment
Adjust controller
Ambient temperature > 25
C
Adjust store air conditioning
Evaporator coil iced up
De-ice coil
Condenser radiator blocked
Remove dust and debris
Thermostat faulty
Replace controller
Temperature probe damaged
or dislocated
Replace or relocate the
temperature probe
Fan not operating
Check and replace the fan
The cabinet lights are not
working
The light switch is OFF
Turn the light switch ON
A LED strip has failed
Replace the LED assembly
An LED PSU has failed
Replace the PSU
An internal circuit breaker has
tripped/failed
Check the wiring and reset
or replace the circuit breaker
Doors are not sliding smoothly
The door is not in its track
Install the door correctly
There is debris in the track
Clean the door tracks
A door glider is damaged or
missing
Have the glider replaced
Lack of lubrication
Apply food grade lubricant to
door tracks
External Condensation
Power supply failed (800 cab.)
Replace power supply
Aluminium parts are corroded
Damage by caustic detergent
Order replacement parts
Service
Personnel Only
The table entries in
italics
indicate actions to be taken only by qualified Service
Personnel.
Содержание IN-5C08-OF
Страница 1: ...Refrigerated Open front Cabinets Curved and Square Formats...
Страница 39: ...IN 5C08 12 OF 39 Future Products Group IN 5C08 5C12 OF SQ...
Страница 40: ...Part No 26126 Rev A November 2014 40 5000 Series Open Front Cabinets IN 5C12 OF...
Страница 41: ...IN 5C08 12 OF 41 Future Products Group...
Страница 42: ...Part No 26126 Rev A November 2014 42 5000 Series Open Front Cabinets...
Страница 43: ...IN 5C08 12 OF 43 Future Products Group...