background image

 17

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание FX Blast Chiller

Страница 1: ...FX BLAST CHILLER ISO 14001 ISO 9001 ...

Страница 2: ...it in such a way as to prevent its escape into the environment harm to human health and to ensure the compliance with the environmental law Guidance is available from the Environment Agency on how to comply with the waste management duty of care 3 The following waste must be stored of separately from other wastes as they are hazardous to the environment refrigerants polyurethane foam oils 4 When a...

Страница 3: ...es FXBC 40 Blast Chiller 40kg capacity with twelve GN1 1 shelves Controller Description The controller is mains voltage 230 50 60 1 00 555941 Timed Chilling LED Set Temperature Chilling LED Storage LED Alarm LED Degree Celsius LED The device has the following operational states ON the controller is switched on and an operating cycle is running stand by the controller is switched on but no operatin...

Страница 4: ...time settings on completion of the programme the time will revert back to the default setting of 90 minutes Temperature chill operation Place the controller in stand by pressing for 2 seconds Ensure that the food probe is inserted into the product prior to commencing the temperature chill programme 3 Press PoS will be displayed and the Timed Chilling LED may be flashing if it is Press again to dis...

Страница 5: ...y to decrease the value or to increase the value Press to return to the followed by to move to the next parameter On completion of the changes press plus to exit or wait 60 seconds First Level Configuration Parameters Mnem Definition Min Max Default Dim FXBC r0 Parameter r7 r8 r9 and Ra hysteresis 0 1 15 0 2 0 K 2 0 r1 Timed positive blast chilling duration 1 600 90 min 90 r2 Timed negative blast ...

Страница 6: ... 90 r2 Timed negative blast chilling duration 1 600 240 min 240 r3 Positive blast chill end point temperature food probe 99 0 99 0 3 0 C 3 0 r4 Negative blast chill end point temperature food probe 99 0 99 0 18 0 C 18 0 r5 Set temperature positive blast chilling duration 1 600 90 min 90 r6 Set temperature negative blast chilling duration 1 600 240 min 240 r7 Positive blast chilling setpoint air te...

Страница 7: ...operation 0 Output a 1 output b 2 comp protection 0 2 1 flag 0 i1 Digital input contact type 0 NO 1 NC 2 no input 0 2 2 flag 1 i2 Digital input alarm delay only if i0 0 or 1 1 no alarm sound 1 120 30 min 30 i3 Digital input effect duration only if i0 0 or 1 1 until input disabled 1 120 15 min 1 i7 Compressor protection deactivation delay only if i0 2 0 120 0 min 0 u0 Relay K2 operation 0 defrostin...

Страница 8: ... Evaporator Coil Coil 013584 00 555412 FXBC10 Evaporator Coil Coil 013524 00 555410 FXBC20 Evaporator Coil Coil 013475 00 555408 FXBC30 FXBC40 Evaporator Fan Motor 00 555374 FXBC10 Evaporator Fan Motor 00 555375 FXBC20 FXBC30 FXBC40 Expansion Valve Body TES2 N 68Z3417 68 15450385 All Models Orifice 00 68 20900 68 207 15451102 FXBC10 FXBC20 Orifice 02 68 2092 68 2072 15451104 FXBC30 FXBC40 Expansio...

Страница 9: ...FXBC 10 Wiring Diagram 8 ...

Страница 10: ...FXBC 10R Wiring Diagram 9 ...

Страница 11: ...FXBC 20R Wiring Diagram 10 ...

Страница 12: ...FXBC 20R Wiring Diagram 11 ...

Страница 13: ...FXBC 30 Wiring Diagram 12 ...

Страница 14: ...13 FXBC 30R Wiring Diagram ...

Страница 15: ...FXBC 40 Wiring Diagram 14 ...

Страница 16: ...FXBC 40R Wiring Diagram 15 ...

Страница 17: ...16 ...

Страница 18: ...17 ...

Страница 19: ...18 ...

Страница 20: ...erfrance com F F T E Germany oster Refrigerator Gmbh el 49 7819907840 Fax 49 7819907844 mail info foster gmbh de F T E Foster Refrigerator ldmedow Road ings Lynn orfolk E30 4JU el 01553 691122 ax 01553 691447 ebsite www fosterrefrigerator co uk O K N P T F W Email sales foster uk com a Division of ITW UK Ltd XBC SM 06 07 F 19 ...

Отзывы: