Environmental Management Policy for Service Manuals and Duets. 

 

Product Support and Installation Contractors 

 

Foster Refrigerator recognises that its activities, products and services can have an adverse impact upon the 
environment. 
The organisation is committed to implementing systems and controls to manage, reduce and eliminate its adverse 
environmental impacts wherever possible, and has formulated an Environmental Policy outlining our core aims. A copy 
of the Environmental Policy is available to all contractors and suppliers upon request. 
 
The organisation is committed to working with suppliers and contractors where their activities have the potential to 
impact upon the environment. To achieve the aims stated in the Environmental Policy we require that all suppliers and 
contractors operate in compliance with the law and are committed to best practice in environmental management. 

 

Product Support and Installation contractors are required to: 
 
1.  Ensure that wherever possible waste is removed from the client’s site, where arrangements are in place all waste 

should be returned to Foster Refrigerator’s premises. In certain circumstances waste may be disposed of on the 
clients site; if permission is given, if the client has arrangements in place for the type of waste. 

 

2.  If arranging for the disposal of your waste, handle, store and dispose of it in such a way as to prevent its escape 

into the environment, harm to human health, and to ensure the compliance with the environmental law. Guidance 
is available from the Environment Agency on how to comply with the waste management ‘duty of care’. 

 

3.  The following waste must be stored of separately from other wastes, as they are hazardous to the environment: 

refrigerants, polyurethane foam, oils. 

 

4.  When arranging for disposal of waste, ensure a waste transfer note or consignment note is completed as 

appropriate. Ensure that all waste is correctly described on the waste note and include the appropriate six-digit 
code from the European Waste Catalogue. Your waste contractor or Foster can provide further information if 
necessary. 

 

5.   Ensure that all waste is removed by a registered waste carrier, a carrier in possession of a waste management 

licence, or a carrier holding an appropriate exemption. Ensure the person receiving the waste at its ultimate 
destination is in receipt of a waste management licence or valid exemption. 

 

6.  Handle and store refrigerants in such a way as to prevent their emission to atmosphere, and ensure they are 

disposed of safely and in accordance with environmental law. 

 

7.  Make arrangements to ensure all staff who handle refrigerants do so at a level of competence consistent with the 

City Guilds 2078 Handling Refrigerants qualification or equivalent qualification. 

 

8. 

Ensure all liquid substances are securely stored to prevent leaks and spill, and are 

not

 disposed of to storm 

drains, foul drain, surface water to soil. 

 

DISPOSAL REQUIREMENTS 

If not disposed of properly all refrigerators have components that can be harmful to the environment.  All old 
refrigerators must be disposed of by appropriately registered and licensed waste contractors, and in accordance with 
national laws and regulations. 
 
 

 

Содержание FX Blast Chiller

Страница 1: ...FX BLAST CHILLER ISO 14001 ISO 9001 ...

Страница 2: ...it in such a way as to prevent its escape into the environment harm to human health and to ensure the compliance with the environmental law Guidance is available from the Environment Agency on how to comply with the waste management duty of care 3 The following waste must be stored of separately from other wastes as they are hazardous to the environment refrigerants polyurethane foam oils 4 When a...

Страница 3: ...es FXBC 40 Blast Chiller 40kg capacity with twelve GN1 1 shelves Controller Description The controller is mains voltage 230 50 60 1 00 555941 Timed Chilling LED Set Temperature Chilling LED Storage LED Alarm LED Degree Celsius LED The device has the following operational states ON the controller is switched on and an operating cycle is running stand by the controller is switched on but no operatin...

Страница 4: ...time settings on completion of the programme the time will revert back to the default setting of 90 minutes Temperature chill operation Place the controller in stand by pressing for 2 seconds Ensure that the food probe is inserted into the product prior to commencing the temperature chill programme 3 Press PoS will be displayed and the Timed Chilling LED may be flashing if it is Press again to dis...

Страница 5: ...y to decrease the value or to increase the value Press to return to the followed by to move to the next parameter On completion of the changes press plus to exit or wait 60 seconds First Level Configuration Parameters Mnem Definition Min Max Default Dim FXBC r0 Parameter r7 r8 r9 and Ra hysteresis 0 1 15 0 2 0 K 2 0 r1 Timed positive blast chilling duration 1 600 90 min 90 r2 Timed negative blast ...

Страница 6: ... 90 r2 Timed negative blast chilling duration 1 600 240 min 240 r3 Positive blast chill end point temperature food probe 99 0 99 0 3 0 C 3 0 r4 Negative blast chill end point temperature food probe 99 0 99 0 18 0 C 18 0 r5 Set temperature positive blast chilling duration 1 600 90 min 90 r6 Set temperature negative blast chilling duration 1 600 240 min 240 r7 Positive blast chilling setpoint air te...

Страница 7: ...operation 0 Output a 1 output b 2 comp protection 0 2 1 flag 0 i1 Digital input contact type 0 NO 1 NC 2 no input 0 2 2 flag 1 i2 Digital input alarm delay only if i0 0 or 1 1 no alarm sound 1 120 30 min 30 i3 Digital input effect duration only if i0 0 or 1 1 until input disabled 1 120 15 min 1 i7 Compressor protection deactivation delay only if i0 2 0 120 0 min 0 u0 Relay K2 operation 0 defrostin...

Страница 8: ... Evaporator Coil Coil 013584 00 555412 FXBC10 Evaporator Coil Coil 013524 00 555410 FXBC20 Evaporator Coil Coil 013475 00 555408 FXBC30 FXBC40 Evaporator Fan Motor 00 555374 FXBC10 Evaporator Fan Motor 00 555375 FXBC20 FXBC30 FXBC40 Expansion Valve Body TES2 N 68Z3417 68 15450385 All Models Orifice 00 68 20900 68 207 15451102 FXBC10 FXBC20 Orifice 02 68 2092 68 2072 15451104 FXBC30 FXBC40 Expansio...

Страница 9: ...FXBC 10 Wiring Diagram 8 ...

Страница 10: ...FXBC 10R Wiring Diagram 9 ...

Страница 11: ...FXBC 20R Wiring Diagram 10 ...

Страница 12: ...FXBC 20R Wiring Diagram 11 ...

Страница 13: ...FXBC 30 Wiring Diagram 12 ...

Страница 14: ...13 FXBC 30R Wiring Diagram ...

Страница 15: ...FXBC 40 Wiring Diagram 14 ...

Страница 16: ...FXBC 40R Wiring Diagram 15 ...

Страница 17: ...16 ...

Страница 18: ...17 ...

Страница 19: ...18 ...

Страница 20: ...erfrance com F F T E Germany oster Refrigerator Gmbh el 49 7819907840 Fax 49 7819907844 mail info foster gmbh de F T E Foster Refrigerator ldmedow Road ings Lynn orfolk E30 4JU el 01553 691122 ax 01553 691447 ebsite www fosterrefrigerator co uk O K N P T F W Email sales foster uk com a Division of ITW UK Ltd XBC SM 06 07 F 19 ...

Отзывы: