11
P86 Alarm
Buzzer Function
NO
YES
NO
P87 Air
Probe
Offset °K
-15
15 0
P88
Coil Probe Offset
°K
-15
15
0
P89 Food
1
Offset
°K
-15
15 0
P90
Food 2 Enable
Function
NO
YES
NO
P91 Food
2
Offset
°K
-15
15 0
P92
Food 3 Enable
Function
NO
YES
NO
P93 Food
3
Offset
°K
-15
15 0
P94 Address
Integer
1
255
255
Parameter Definitions
Pre-Chill
P01
Pre-Chill Enable
The air temperature, which the air probe must read before the condensing system is de-energised in the chill
mode of the Pre-Chill Program.
Range -15°C to 15°C.
P02 Chill
Time
The period Pre-Chill is in the chill mode prior entering the Hold Mode.
Range 5 minutes to 60 minutes.
P03 Hold
Temp
The temperature, which the air probe must read before the condensing system is de-energised in the Hold mode
of the Pre-Chill program.
Range -15°C to 15°C.
Soft-Chill
P04 Air
Temp
The temperature, which the air probe must read before the condensing system is de-energised in the chill mode
of the Soft-Chill Program.
Range -10°C to 15°C.
P05 Chill
Time
The period Soft Chill program is in chill mode prior to entering Hold mode in a time based chill cycle.
Range 5 minutes to 480 minutes.
P06 Chill
Temp
The temperature, which the Food Probe 1 must read before the condensing system is de-energised in the chill
mode of the Soft Chill program prior to entering the Hold mode of a temperature based cycle.
Range -5°C to 15°C.
P07 Hold
Temp
The temperature, which the air probe must read before the condensing system is de-energised in the Hold mode
of the Soft Chill program.
Range -5°C to 15°C.
Hard Chill
P08 Air
Temp
The temperature, which the air probe must read before the condensing system is de-energised in the chill mode
of the Hard Chill Program.
Range -20°C to 15°C.
P09 Chill
Time
The period Hard Chill program is in chill mode prior to entering Hold mode in a time based chill cycle.
Range 5 minutes to 480 minutes.
P10 Chill
Temp
The temperature, which the Food Probe 1 must read before the condensing system is de-energised in the chill
mode of the Hard Chill program prior to entering the Hold mode of a temperature based cycle.
Range -15°C to 15°C.
P11 Hold
Temp
The temperature, which the air probe must read before the condensing system is de-energised in the Hold mode
of the Hard Chill program.
Range -15°C to 15°C.
P12 Change
Time
The percentage period of a time based chill cycle, which is to have passed before automatically adjusting the air
temperature set point to 1°C.The range is adjustable in 5% increments.
Range 05% to 95%.
Содержание BC 21
Страница 1: ...RBC20 60 Blast Chiller ...
Страница 24: ...23 COMPRESSOR WIRING RBC20 60 ...
Страница 25: ...RBC20 60 1 of 2 Wiring Diagram 24 ...
Страница 26: ...RBC20 60 2 of 2 Wiring Diagram 25 ...
Страница 27: ...RBC20 60R 1 of 2 Wiring Diagram 26 ...
Страница 28: ...27 RBC20 60R 2 of 2 Wiring Diagram ...
Страница 29: ......
Страница 30: ...2 ...
Страница 31: ...3 ...