20

Technical Data 

 

 RBC20-60 

RBC20-60R 

Nominal Chilling Capacity 

60Kg 

60Kg 

Duty @ -15°C 

3800w 

3800w 

Fans 3 

Evaporating Temperature 

-15°C 

-15°C 

HP Switch Setting 

 

 

Refrigerant Control 

TEV 

TEV 

Refrigerant R404a 

R404a 

Refrigerant Quantity 

 

 

System 1 

1900grms 

 

System 2 

1900grms 

 

Electrical Supply 

400/3/50 – 16amp 

230/1/50 13 amp (Fans & Defrost)  

Total Heat Rejection 

1500w 

 

 

Important Note 

There are two refrigeration systems on this model  

Refrigerant used is R404A. 
The RBC20-60 has two separate refrigeration systems comprising, two condensing units, a twin circuit condenser (see 
below) and a twin circuit evaporator. (See page 21for assembly details and page 22 for schematic dual circuit refrigeration 
layout). 
The condenser fan on system 2 is controlled by the HP switch, which is set at 

18 BAR

 with a 

3 BAR 

diff. 

The RBC20-60R has the same refrigeration systems but the condensing units are remotely sited. 

 

 

The parameter ‘Capacity Enable’ is set to ‘AUTO’ to allow for both condensing units to be running at the start of the chill 
cycle therefore maximising the heat extraction from the product. On reaching ‘HOLD’ one of the condensing units will shut 
down. During the ‘HOLD’ mode one compressor will control the temperature throughout unless the temperature exceeds 
the capacity control limit. 

 

Refrigerant control is by expansion valve to control the correct amount of refrigerant required to meet the demand of the 
evaporator. (See page 21 for assembly detail).

  

Expansion Valve Setting (Superheat) 

Adjust the superheat by turning the expansion valve setting spindle anti clockwise until back seated then turn the setting 
spindle clockwise 

THREE FULL TURNS IN

.   

 

CONDENSING UNIT ASSEMBLY  RBC20-60 

System 2 

System 1 

HP Switch 

Содержание BC 21

Страница 1: ...RBC20 60 Blast Chiller ...

Страница 2: ...m the product quickly The air temperature then increases to 3 c for the final 30 of the time to reduce surface damage and ensure quality Hard Chill Max Hard chill max brings down the food temperature to 3 c in no more than 90 minutes and is used for chilling high density or high fat content food such as meat joints stews or packaged products The air temperature during the cycle is allowed to go do...

Страница 3: ...external drain The cabinet is delivered with the legs secured to the base of the cabinet Controller Technical Detail The FCC controller is a three piece unit made up of the Front Display and Dial Shaft Encoder Mother Board plus Evaporator Food and Air temperature probes The front display PCB and the CPU Switching PCB unit are interconnected by a ribbon cable The membrane attached to the front prov...

Страница 4: ...ress and release the dial for the program to start The program starts with the screen on the left being displayed for 2 minutes After which the intelligent probe determines if the cycle is controlled by time displayed by the screen in the middle or by temperature as displayed by the screen on the right On completion of the program the controller will cause the blast chiller to enter the Hold Mode ...

Страница 5: ...ress and release the dial to move to the time set see below right Rotate the dial clockwise to increase the time anticlockwise to decrease Once the time has been selected press and release the dial and CHILL TEMP will be highlighted On completion press and hold the dial for 2 seconds to return to the program selection screen to continue press and release the dial for the program to start On comple...

Страница 6: ... service screen below right Press and release the dial to move to the displayed time in hours and minutes rotate the dial to alter the time once the correct time has been achieved press and release the dial to move to DAY If it is necessary to change the day month and year change the settings using the same procedure for setting the time On completion press and hold the dial for 2 seconds to retur...

Страница 7: ...dial for two seconds the display returns to the program selection There are Three main programmes RBC 20 60 Blast Chiller Soft Chill for the safe chilling of delicate products such as gateaux and patisserie items and high water content items such as vegetables rice and pasta Hard Chill For general purpose chilling The Hard Chill cycle is ideal for chilling standard products such as meat pies lasag...

Страница 8: ... connection Display Data Man Machine RJ54 Type 4 way connection Logger 4 way RS 485 connections Service Information Refer to the operating instructions on page 4 for operating instructions When mains electrical power is first applied to the controller it will carry out a self test function for approximately 3 seconds to ensure that there are good connections between the component parts During this...

Страница 9: ... chill process Relay 1 COMPRESSOR Relay 2 FAN1 Relay 3 FAN2 Relay 4 DEFROST Relay 5 ALARM Relay 6 CCAP Capacity Control and Relay 7 UV L will all be switched on and of automatically in a pre determined manner to simulate program operation whether they are connected or not The test is based around an algorithm built into the software Prior to starting the program it is advisable to place a probe in...

Страница 10: ... 9 9 PROFESSIONAL 2 U U U U U 9 9 PROFESSIONAL 3 U U U U U 9 9 DEFROST 9 9 9 9 9 9 9 UV SANITISATION OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL INFORMATION OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL Parameter Access From the profile screen once the selection has been made press and release the dial to access the parameter list The screen will display the par...

Страница 11: ... Chill Time Minimum Minutes 5 60 5 P49 Chill Time Maximum Minutes 60 480 240 P50 Chill Temp Std C P51 P52 3 P51 Chill Temp Minimum C 20 5 10 P52 Chill Temp Maximum C 5 15 5 P53 Hold Temp Std C P54 P55 3 P54 Hold Temp Minimum C 10 0 0 P55 Hold Temp Maximum C 0 10 10 P56 Change Time 5 95 80 P57 Change Temp 5 95 80 SYSTEM P58 UV Light Enable Minutes 0 120 0 P59 HACCP Enable Function NO YES NO P60 Sho...

Страница 12: ...p The temperature which the Food Probe 1 must read before the condensing system is de energised in the chill mode of the Soft Chill program prior to entering the Hold mode of a temperature based cycle Range 5 C to 15 C P07 Hold Temp The temperature which the air probe must read before the condensing system is de energised in the Hold mode of the Soft Chill program Range 5 C to 15 C Hard Chill P08 ...

Страница 13: ...nutes to 480 minutes P20 Chill Temp The temperature which the Food Probe 1 must read before the condensing system is de energised in the chill mode of the Shock Freeze program prior to entering the Hold mode of a temperature based cycle Range 15 C to 15 C P21 Hold Temp The temperature which the air probe must read before the condensing system is de energised in the Hold mode of the Shock Freeze pr...

Страница 14: ...ercentage of a temperature based chill cycle which is passed before automatically adjusting the air temperature set point to 1 C The range is adjustable in 5 increments 3 Change Temp Range 5 to 95 Pr P3 The standard temperature which the air probe must read before the condensing system is de energised in the chill mode of the Professional 2 Program ofessional 2 4 Air Temp Std Range 20 C to 15 C P3...

Страница 15: ...he chill mode of the Professional 3 Program ofessional 3 6 Air Temp Std Range 20 C to 15 C P47 Chill Time Std The standard period Professional 3 program is in chill mode prior to entering Hold mode in a time based chill cycle Range 5 minutes to 480 minutes P48 Chill Time Minimum The minimum period Professional 3 program is in chill mode prior to entering Hold mode in a time based chill cycle that ...

Страница 16: ...ck Freeze mode Function YES enables NO disables P61 Chill Hysteresis Allowable temperature increase from chill cycle air temperature Set Point before switching on the refrigeration system Range 02 K to 20 K P62 Hold Hysteresis Allowable temperature increase from hold cycle air temperature Set Point before switching on the refrigeration system Range 02 K to 20 K P63 APM Time Automatic Program Mode ...

Страница 17: ...time that the Defrost period will last before reverting to the chill or hold cycle Range 01minute to 60 minutes P72 Defrost End Temp The coil temperature as detected by the evaporator probe at which the Defrost function will terminate before reverting back to chill or hold mode Range 0 C to 10 C P73 Drain Time The time period following the defrost routine terminated by time or temperature that is ...

Страница 18: ...ilarly if the measured hold temperature is greater than or equal to program hold set point hold hysteresis high alarm temperature value the alarm will sound Range 1 C to 50 C P83 High Alarm Delay The delay period between a temperature alarm condition occurring 00 minutes Instantaneous audible alarm 01 to 120 minutes period of delay P84 Alarm Time The length of time which the alarm will sound for a...

Страница 19: ...ycle if safe to do so The distinction between an alarm and a warning is that a warning may be a non critical occurrence such as door open or temporary power failure An alarm would be for a system failure such as a probe fault or high pressure fault which would require positive intervention High pressure developing in the refrigeration system as a result of to high food temperature condenser fan fa...

Страница 20: ...econds from start Relay 6 is energised after 360 seconds from start of test for 90 seconds de energises 450 seconds from start Relay 7 is energised after 570 seconds from start of test for 20 seconds de energises 590 seconds from start All relays are de energised on completion of the test At any point during the test pressing and holding the dial for 2 seconds can stop it The test will be terminat...

Страница 21: ... switch which is set at 18 BAR with a 3 BAR diff The RBC20 60R has the same refrigeration systems but the condensing units are remotely sited The parameter Capacity Enable is set to AUTO to allow for both condensing units to be running at the start of the chill cycle therefore maximising the heat extraction from the product On reaching HOLD one of the condensing units will shut down During the HOL...

Страница 22: ...21 EVAPORATOR ASSEMBLY RBC20 60 SERVICE PLATE SYSTEM 1 SYSTEM 2 PHIALS MUST BE FITTED IN THE HORIZONTAL POSITION AND CORK TAPED FAN PLATE ...

Страница 23: ...CONDENSER DUAL CIRCUIT COMPRESSOR COMPRESSOR EVAPORATOR DUAL CIRCUIT SIGHT GLASS SOL VALVE DRIER SIGHT GLASS SOL VALVE DRIER EXP VALVE EXP VALVE LIQUID RECEIVER LIQUID RECEIVER HP SW HP SW LP SW LP SW PHIAL PHIAL STAT EQUALISING LINE EQUALISING LINE ...

Страница 24: ...23 COMPRESSOR WIRING RBC20 60 ...

Страница 25: ...RBC20 60 1 of 2 Wiring Diagram 24 ...

Страница 26: ...RBC20 60 2 of 2 Wiring Diagram 25 ...

Страница 27: ...RBC20 60R 1 of 2 Wiring Diagram 26 ...

Страница 28: ...27 RBC20 60R 2 of 2 Wiring Diagram ...

Страница 29: ......

Страница 30: ...2 ...

Страница 31: ...3 ...

Страница 32: ...com F F T Germany oster Refrigerator Germany el 0781 96 93 00 Fax 0781 96 93 019 Email info fosterrefrigerator de F T oster Refrigerator ldmedow Road King s Lynn orfolk Pe30 4JU ngland el 01553 691122 ax 01553 691447 ebsite www fosterrifrigerator co uk F O N E T F W Email sales foster uk com a Division of ITW UK Ltd BC20 SM 0107 R ...

Отзывы: