25
ENGLISH
INSTALLER INSTRUCTIONS
• The distance of the cooker hob
from the back edge must be at least
50 mm;
• The distance of the cooker hob from
the walls that exceed worktop height
must be at least 100 mm;
• Make sure that there is a minimum
distance of 750 mm from the burner
to any shelf placed vertically above it;
50
750
100
Fig. 3:
cooker hob distances
• Make sure that any exhaust appliances installed above the cooker hob are posi-
tioned according to the measurements indicated in the hood instructions booklet.
• Carefully position the supplied in-
sulating gasket along the external
perimeter of the hole created on the
worktop, trying to make it adhere
along the entire surface by slightly
pressing it by hand [
Fig. 4
].
• Once these operations have been
completed, use the supplied brack-
ets to fasten the hob to the structure.
Refer to the “
Fastening the cook-
er hob to the cabinet
” paragraph
[
Page 26
].
Fig. 4:
positioning the insulating gasket
6.2 Installation on the support structure (worktop) of a flush built-in cooker
hob (flush-mount edge)
This type of appliance requires
milling on the 1.5 mm deep worktop,
which measurements are indicated in the top drawing, identifiable in the section
Gas cooker hobs summary - models with "flush" built-in
[
Page 182
].
The step is necessary to house the cooker hub edge so that it is "flush" with the
worktop.