33
ENGLISH
INSTALLER INSTRUCTIONS
IMPORTANT:
After adjusting for use with a gas that is different from the initial testing
one, replace the label on appliance housing with the one that corresponds to the new
gas type.
12. Adjustment of the minimum
Instructions for urban and methane gas
1. Light the burner and bring it to the minimum
position.
2. Remove the gas tap knob and turn the adjust-
ment screw [
Fig. 8
] inside or on the side of the
tap rod (depending on the model), until a regular
minimum flame is obtained.
3. Re-assemble the knob and verify burner flame
stability (when quickly rotating the hand from
maximum to minimum position the flame must
not shut off).
4. Repeat the operation on all gas taps.
Fig. 8:
adjustment of the minimum
Instructions for liquid gas (LPG)
Tighten the screw inside, or on the side of the tap (depending on the mode), rod
clockwise completely.
13. Electrical connection of the cooker hob
IMPORTANT:
Before completing the following operation, always make sure that the
voltage and sizing of the power supply line correspond to the characteristics indicated
on the place located under the housing of the appliance.
This plate must never be
removed.