Fitting of Additional Key Exchange
Modules
The XMA/XMSA is supplied with its own
Installation Instructions.
Conversion from DM to XM or DMS to XMS
It is possible to convert a DM to an XM or a DMS
to an XMS. However, this must to be done with
care as the sequence may require modification.
If the DM/DMS needs to be changed to an XM/
XMS, contact Fortress Interlocks.
Conversion from DM to BM or DMS to BMS
It is possible to convert a DM to an BM or a DMS
to an BMS. However, this must to be done with
care as the sequence may require modification.
If the DM/DMS needs to be changed to an BM/
BMS, contact Fortress Interlocks.
Back of Board (BOB) Mounting
The M-BOB is supplied with its own Installation
and Maintenance Instructions. Only applicable
to the DM product.
Commissioning
Mechanical Function Test
Assuming Standard Sequencing:
1 Start with the primary key inserted and the
door closed and locked.
2 Remove the first secondary key (If DM2/DMS2
or more).
3 Check that the primary key is trapped in
position and the door remains locked.
4 Remove the remaining secondary key(s) (If
DM3/DMS3 or more).
5 Check that the primary key is trapped in
position and the door remains locked, upon
removal of each secondary key .
6 Insert and turn all of the secondary key(s).
7 Check that the primary key can only be
removed when all the secondary key(s)
are inserted.
8 Check that the door can be opened.
9 Ensure that when the actuator is removed
from the head, the primary key cannot be
fully turned 120 degrees.
Service and Inspection
Regular weekly inspection of the following is
necessary to ensure trouble-free, lasting
operation:
1 Secure mounting of components.
2 Debris and wear .
3 All locks should be lubricated with WD40.
There are no user serviceable parts in a DM/
DMS module. If damage or wear is found, the
whole module must be replaced.
Disposal
The DM/DMS does not contain any certified
hazardous materials so should be disposed of
as industrial waste.
Liability coverage is voided under the
following conditions:
1 If these instructions are not followed.
2 Non-compliance with safety regulations.
3 Installation not performed by authorised
personnel.
4 Non-implementation of functional checks.
Installation Instructions
DM/DMS
Door Interlock
Fortress Interlocks Ltd
2 Inverclyde Drive
Wolverhampton
West Midlands
WV4 6FB
tel: +44 (0) 1902 349000
fax: +44 (0) 1902 349090
email: [email protected]
web: www.fortressinterlocks.com
Part Numbering
The
DM
uses a logical part numbering
system: -
Example: DM3-CLIS-F
DM
: Generic Product Type (
D
oor
M
odule).
3
:
Number of CL/ML Locks (
1
to
10
)
or
A
for add-on module used to
convert an XM/BM to a DM.
-
Separator.
CL
: Lock Type (
CL
/
ML
).
I
:
Stainless Steel CL/ML
I
nternals.
S
:
Dust Cover Option (
S
for Stainless
Steel or
N
for no dust cover).
-
Separator.
F
:
F for Fixed Actuator,
S
for Self-
Aligning Actuator or
H
for Hand
Operated Actuator.
M-BOB
:
Back of Board Mounting
Adaptor.
The
DMS
uses a logical part numbering
system: -
Example:
DMS2-MLSS-H
DMS
:Generic Product Type (
D
oor
M
odule
S
tainless Steel).
2
:
Number of CLS/MLS Locks (
1
to
5
) or
A
for add-on module used to
convert an XMS/BMS to a DMS.
-
Separator.
ML
: Lock Type (
CLS
/
MLS
).
S
:
Full
S
tainless Steel CLS/MLS.
S
:
S
tainless Steel Dust Cover as
standard.
-
Separator.
H
:
F
for Fixed Actuator,
S
for Self-
Aligning Actuator or
H
for Hand
Operated Actuator.