background image

Fitting of Additional Key Exchange
Modules

The XMA/XMSA is supplied with its own

Installation Instructions.

Conversion from DM to XM or DMS to XMS

It is possible to convert a DM to an XM or a DMS

to an XMS. However, this must to be done with

care as the sequence may require modification.

If the DM/DMS needs to be changed to an XM/

XMS, contact Fortress Interlocks.

Conversion from DM to BM or DMS to BMS

It is possible to convert a DM to an BM or a DMS

to an BMS. However, this must to be done with

care as the sequence may require modification.

If the DM/DMS needs to be changed to an BM/

BMS, contact Fortress Interlocks.

Back of Board (BOB) Mounting

The M-BOB is supplied with its own Installation

and Maintenance Instructions.  Only applicable

to the DM product.

Commissioning
Mechanical Function Test

Assuming Standard Sequencing:

1 Start with the primary key inserted and the

door closed and locked.

2 Remove the first secondary key (If DM2/DMS2

or more).

3 Check that the primary key is trapped in

position and the door remains locked.

4 Remove the remaining secondary key(s) (If

DM3/DMS3 or more).

5 Check that the primary key is trapped in

position and the door remains locked, upon

removal of each secondary key .

6 Insert and turn all of the secondary key(s).

7 Check that the primary key can only be

removed when all the secondary key(s)

are inserted.

8 Check that the door can be opened.

9 Ensure that when the actuator is removed

from the head, the primary key cannot be

fully turned 120 degrees.

Service and Inspection

Regular weekly inspection of the following is

necessary to ensure trouble-free, lasting

operation:

1 Secure mounting of components.

2 Debris and wear .

3 All locks should be lubricated with WD40.
There are no user serviceable parts in a DM/

DMS module. If damage or wear is found, the

whole module must be replaced.

Disposal

The DM/DMS does not contain any certified

hazardous materials so should be disposed of

as industrial waste.

Liability coverage is voided under the
following conditions:

1 If these instructions are not followed.

2 Non-compliance with safety regulations.

3 Installation not performed by authorised

personnel.

4 Non-implementation of functional checks.

Installation Instructions

DM/DMS

 

Door Interlock

Fortress Interlocks Ltd

2 Inverclyde Drive

Wolverhampton

West Midlands

WV4 6FB

tel: +44 (0) 1902  349000

fax: +44 (0) 1902 349090

email: [email protected]

web: www.fortressinterlocks.com

Part Numbering

The

 DM

 uses a logical part numbering

system: - 

Example: DM3-CLIS-F

DM

: Generic Product  Type (

D

oor

M

odule).

3

:

Number of CL/ML Locks (

1

 to 

10

)

or 

A

 for add-on module used to

convert an XM/BM to a DM.

-

Separator.

CL

: Lock Type  (

CL

/

ML

).

I

:

Stainless Steel CL/ML 

I

nternals.

S

:

Dust Cover Option (

S

 for Stainless

Steel or 

N

 for no dust cover).

-

Separator.

F

:

F for Fixed  Actuator, 

S

 for Self-

Aligning Actuator  or 

H

 for Hand

Operated Actuator.

M-BOB

:

Back of Board Mounting

Adaptor.

The

 DMS

 uses a logical part numbering

system: - 

Example: 

DMS2-MLSS-H

DMS

:Generic Product  Type (

D

oor

M

odule 

S

tainless Steel).

2

:

Number of CLS/MLS Locks (

1

 to

5

) or 

A

 for add-on module used to

convert an XMS/BMS to a DMS.

-

Separator.

ML

: Lock Type  (

CLS

/

MLS

).

S

:

Full 

S

tainless Steel CLS/MLS.

S

:

S

tainless Steel Dust Cover as

standard.

-

Separator.

H

:

F

 for Fixed  Actuator, 

S

 for Self-

Aligning Actuator  or 

H

 for Hand

Operated Actuator.

Содержание DM4-CLIN

Страница 1: ...eel Lock Mechanism CLS MLS locks Full Stainless Steel Key All Stainless steel Tools and Fixings Required 2 off Cap head hexagonal head bolts for each module Front of Board mounting M6 x 25 or x 1 Back...

Страница 2: ...following is necessary to ensure trouble free lasting operation 1 Secure mounting of components 2 Debris and wear 3 All locks should be lubricated with WD40 There are no user serviceable parts in a D...

Страница 3: ...roduct Fortress Interlocks Ltd 2 Inverclyde Drive Wolverhampton West Midlands WV4 6FB tel 44 0 1902 349000 fax 44 0 1902 349090 email sales fortressinterlocks com web www fortressinterlocks com 2D Gen...

Страница 4: ...nge state and the door can be opened After operation of the Internal Release the machine must isolated and investigated to establish why the Internal Release had t o be used Remedial action should be...

Страница 5: ...use Komplett rostfreier Stahl Einbauten Komplett rostfreier Stahl Stellglieder Komplett rostfreier Stahl Verriegelungsmechanik CLS MLS Verriegelungen Komplett rostfreier Stahl Schl ssel Komplett rostf...

Страница 6: ...werden um einen st rungsfreien lang anhaltenden Betrieb sicherzustellen 1 Sichere Befestigung der Elemente 2 Verschlei der Teile 3 Alle Verriegelungen m ssen mit Schmiermittel des Typs WD40 gefettet w...

Страница 7: ...email sales fortress interlocks co uk web www fortressinterlocks com DM DMS Schubriegelschloss Installationsanweisungen Zweidimensionale allgemeine Zeichnung f r das DM Produkt Zweidimensionale allge...