- 656 -
11.2.7.4 Configuring sFlow Sampler Configuration Page
sFlow agent collects statistical packet-based sampling of switched flows and sends them to the
configured receivers. A data source configured to collect flow samples is called a sampler.
Selection Criteria
sFlow Sampler Datasource(Slot/Port)
- sFlowDataSource for this flow sampler. This Agent will
support Physical ports only.
Configurable Data
Receiver Index
- The sFlow Receiver for this flow sampler. If set to 0, the sampler configuration is
set to default and the sampler is deleted. Only active receivers can be set. If a receiver expires then
all samplers associated with the receiver will also expire. Allowed range is (1 to 8 )
Sampling Rate
- The statistical sampling rate for packet sampling from this source. A sampling rate
of 1 counts all packets. A sampling rate of 0 disables sampling. Allowed range is (1024 to 65536 )
Maximum Header Size
- The maximum number of bytes that should be copied from a sampled
packet. Allowed range is (20 to 256 )
Non-Configurable Data
Slot/Port
- The interface for which data is being displayed.
Receiver Index
- The sFlowReceiver for this sFlow sampler.
Sampling Rate
- The statistical sampling rate for packet sampling from this source.
Maximum Header Size
- The maximum number of bytes that should be copied from a sampled
packet.
Command Buttons
Submit
- Send the updated data to the switch and cause the changes to take effect on the switch.
Refresh
- Refresh the data on the screen with present state of data in the switch.
Содержание FortiSwitch-548B v. 5.2.0.2
Страница 1: ...FortiSwitch 548B Version 5 2 0 2 Administration Guide...
Страница 865: ...865 11 6 4 Viewing IPv6 Interface Statistics Page...
Страница 969: ...www fortinet com...