FortiGate-7060E System Management Modules
Fortinet Technologies Inc.
Description
SMC CLI Commands
IPMI commands
(chip_erase). Available on the
passive module.
Disable a module's comlog.
Available on the passive
module.
comlog disable
fortinetoem comlog clear
Enable comlog. Available on
the passive module.
comlog enable
fortinetoem comlog clear
Set comlog baud rate.
<speed>
can be 9600, 19200,
38400,57600, 115200, or
expressed as level 1 to 4.
Available on the passive
module.
comlog setbaud <speed>
fortinetoem comlog setbaud
<speed>
System event log (SEL)
The SMC in each FIM and FPM generates system event log (SEL) messages that record system events as they occur.
All SEL messages are stored by individual FIM and FPM SMCs. They are also all collected and stored by the SMM
SMC. From the SMM you can use the following commands from the active or passive SMM to view and clear SEL
messages.
Operation
SMC CLI Commands
IPMI Commands
Display the local SEL for a
module.
sel <slot>
sel list
sel elist
-v sel list
Clear the local SEL.
sel clear
sel clear
Get SEL information.
N/A
sel info
Get SEL time
time get
sel time get
Set SEL time
time set <yyyy/mm/dd
hh:mm:ss>
sel time set
Sensor data record (SDR)
The sensor data record (SDR) contains static information about the sensors in all parts of the chassis including the FIMs
and FPMs. Information includes the Sensor ID string, sensor type, sensor event/reading type, entity ID, entity instance,
sensor unit, reading linearization parameters, sensor thresholds, and so on. The following commands display
information stored in the SDR.