FortiGate-7060E hardware assembly and rack mounting
Fortinet Technologies Inc.
FortiGate-7060E cooling air flow and minimum air flow clearance
Cool air
Intake
Front
FortiGate-7121F chassis (side View)
Fan
Trays
Fan
Trays
100 mm
675 mm
Warm Air
Exhaust
Back
100 mm
Cool air enters the chassis through the chassis front panel and warm air exhausts out the back. For optimal cooling,
allow 100 mm of clearance at the front and back of the chassis.
Inserting FIMs and FPMs
All FortiGate-7060E chassis are shipped with a protective front panel installed in the chassis to protect internal chassis
components. This panel must be removed before you install FIMs and FPMs.
Insert FIMs into chassis slots 1 and 2. Insert FPMs into chassis slots 3, 4, 5, and 6.
FortiGate-7060E 6.4.2 System Guide