Turning the module on and off
FIM-7904E interface module
For example, to split the B1 interface of the FIM-7904E in slot 1 (this interface is named 1-B1) and the B1 and B4
interfaces of the FIM-7904E in slot 2 (these interfaces are named 2-B1 and 2-B4) connect to the CLI of your
FortiGate-7000 system using the management IP and enter the following command:
config system global
set split-port 1-B1 2-B1 2-B4
end
After you enter the command, the FortiGate-7000 reboots and when it comes up:
l
The 1-B1 interface will no longer be available. Instead the 1-B1/1, 1-B1/2, 1-B1/3, and 1-B1/4 interfaces will be
available.
l
The 2-B1 interface will no longer be available. Instead the 2-B1/1, 2-B1/2, 2-B1/3, and 2-B1/4 interfaces will be
available.
l
The 2-B4 interface will no longer be available. Instead the 2-B4/1, 2-B4/2, 2-B4/3, and 2-B4/4 interfaces will be
available.
You can now connect breakout cables to these interfaces and configure traffic between them just like any other
FortiGate interface.
Turning the module on and off
You can use the front panel power button to turn the module power on or off. If the module is powered on, press
the power switch to turn it off. If the module is turned off and installed in a chassis slot, press the power button to
turn it on.
NMI switch
When working with Fortinet Support to troubleshoot problems with the FIM-7904E you can use the front panel
non-maskable interrupt (NMI) switch to assist with troubleshooting. Pressing this switch causes the software to
dump registers/backtraces to the console. After the data is dumped the board reboots. While the board is
rebooting, traffic is temporarily blocked. The board should restart normally and traffic can resume once its up and
running.
FIM-7904E hardware architecture
The FIM-7904E includes an integrated switch fabric (ISF) that connects the front panel interfaces to the DP2
session-aware load balancers and to the chassis backplanes. The ISF also allows the DP2 processors to
distribute sessions amoung all NP6 processors on the FPM modules in the same chassis.