TM
27
TM
Connection to the ground of electronic standard key FT3328 and electronic vandal resistant key FT3188
• In case of an error during programming, press button
“key” to cancel the operation being carried out.
• Always remember to press “E” at the end of each operation,
both during the programming stage and during normal
operation.
• The insertion of the super code cancels all the previous
programming.
2) Initial programming of relay codes
In order to proceed with programming of relay codes it is necessary
to know the supercode. During programming, the red LED on the
keypad will be on. In case of an error the led will turn off after a brief
flashing, so programming must be started again from the beginning.
Procedure for initial programming of relay codes
1) Key in “
0
” e “
E
” (start of programming control).
2) Make sure the red LED is on.
3) Key in the
supercode
(entered in point 1), followed by “
E
”.
4) Key in the identification
number
of the relay (
1
or
2
)
followed by “
E
”.
5) Key in the operation
mode
(see point 5), then “
E
”.
6) Key in the
new code
to be entered, followed by “
E
”.
7) Check that the LED has turned off.
E.g.:
to insert code 55127 for relay 1, in bistable mode (on/off), key in the
following:
0 E
start of programming
12345 E
supercode
1 E
identification of relay 1
0 E
bistable operation mode
55127 E
new code
3) Use of relay codes
After carrying out the above operation, relay 1 can be activated
simply by keying in: 55127 E.
In this example, the operation mode was programmed as 0, i.e.
relay operation is bistable (on/off). To activate monostable mode
operation, see point 5.
• Up to 300 codes can be inserted on either relay 1 or 2 as
desired. If an attempt is made to insert a code which has
already been stored in the memory, an error is indicated.
4) Deletion of relay codes
The following procedure must be followed to delete a previously set
code from the memory:
1) Key “
0
” “
E
” (start of programming control).
2) Make sure the LED is on.
3) Key in the
supercode
(see point 1), followed by “
E
”.
4) Key in “
0
” (code deletion), followed by “
E
”.
5) Key in the
code
you wish to delete, then “
E
”.
6) Check that the LED is turned off.
E.g.:
to delete code 55127, key in the following:
0 E
start of programming
12345 E
supercode
0 E
deletion procedure
55127 E
code to be deleted
5) Bistable/monostable operation
From previous programmings it will be noted that it is possible to
obtain bistable (on/off) or monostable (timed) closure, of the relays
by programming the desired time value in seconds.
Bistable mode:
if the value “
0
” is programmed, the relay will be activated with the
first correct execution of the code, and will be deactivated with the
next correct execution.
Monostable mode:
if a value from
1
to
99
is programmed, the relay will be activated
with the correct execution of the code, and will be deactivated after
the programmed time (1” - 90”).
Modification of the relay timing:
Delate the relay code as indicated in point 4 before modifying the
relay timing.
E.g.:
if the relay “1” is activated by the code 55127 and is bistable, to
transform it into monostable mode follow this procedure.
1) Delate de code by keying in:
0 E
start programming
12345 E
supercode
0 E
cancellation procedure
55127 E
code to be delated.
Содержание DIGI-2
Страница 1: ...D I G I 2 S Y S T E M T E C H N I C A L M A N U A L ...
Страница 17: ...TM 15 TM U P yellow green A L T O A L T O U P MIC U P 8 9 10 11 12 13 ...
Страница 18: ...TM 16 U P UP U P UP ALTO UP U P U P 1 2 14 15 16 SOLUTION A SOLUTION B ...
Страница 36: ...TM 34 2 3 1 6 5 4 5 Installation of monitor on desk support FT5712 ...
Страница 52: ...TM 50 System with 1 standard Series video entrance Diagram 1 Only required if using push to exit button ...
Страница 53: ...TM 51 TM System with 1 standard Series audio entrance Diagram 2 Only required if using push to exit button ...
Страница 54: ...TM 52 System with 2 standard Series video entrances Diagram 3 Only required if using push to exit button ...
Страница 55: ...TM 53 TM System with 2 standard Series audio entrances Diagram 4 Only required if using push to exit button ...
Страница 57: ...TM 55 TM ...
Страница 59: ...TM 57 TM ...
Страница 61: ...TM 59 TM ...
Страница 62: ...TM 60 Connection of a MAX 9 riser branches for each Mixer power supply FT4896 Diagram 8 ...
Страница 64: ...TM 62 Connection in cascade of several internal units up to 25 for branch from FT4896 Diagram 10 ...
Страница 65: ...TM 63 TM ...
Страница 80: ...TECHNICAL MANUAL 1 a edition 01 2008 Cod 22591745 ...