5D) INSERTING A LIST ( DOWNLOAD )
By means of the software FT1249/A it is possible to enter the list with the
User name
and
Code
fields, in increasing alphabetical order, in the module FT3072/A.
It is necessary to carry out the following operations:
5C) MULTIDOWNLOAD
It is possible to create an RS485 system with digital call modules FT3072/A to upload or
download an user name list on any of the modules on this system, using a pc upgraded
with software FT1249/A version 2.2 or later.
Each module must have different ID CODE (see paragraph 4A-4).
5B) CANCELLING A NAME BY MEANS OF FT1230
ON DISPLAY
DESCRIPTION
OPERATION
BIANCHINI
PRESS TO
CALL
DELETE
TENANT?
DELETE
Followed by:
ROSSI
PRESS TO
CALL
SELECT NAME
BY
Select the user name
you want to eliminate
by scrolling the list
with the
keys.
(EXAMPLE:
BIANCHINI
)
Press the
NAME
key of FT1230.
Press the
ENTER
key
of FT1230 to confirm
elimination or
ESC
to cancel.
➞
Confirmation of cancellation
is requested.
The name has been
eliminated.
The next tenant in
alphabetical order is diplayed.
It is necessary to set the
CALL MODE
as Standard
on the software FT1249/A.
If the download has
terminated successfully.
If some anomaly has
occurred during the
download.
ON DISPLAY
DESCRIPTION
OPERATION
Connect the small cable
provided with the software
FT1249/A to terminals TX /
RX / - ( or D / D- if there
is an RS485 line ).
Run the software
FT1249/A.
Consult the in-line Guide
for the settings required.
Compile the list with the
User name and Code fields
in the software FT1249/A,
or load an existing one.
Press the Download
pushbutton in software
FT1249/A.
SELECT NAME
BY
SELECT NAME
BY
DOWNLOAD
ENDED
Or:
DOWNLOAD
FAILED
↑
↓
↑
↓
INITIAL CONDITION
Module supplied
in stand-by condition.
SELECT NAME
BY
↑
↓
INITIAL CONDITION
5E) READING THE STORED LIST ( UPLOAD )
By means of the software FT1249/A it is possible to read the list with the User
name and Code fields from module FT3072/A. It is necessary to carry out the fol-
lowing operations:
Module supplied in
stand-by condition.
SELECT NAME
BY
↑
↓
SELECT NAME
BY
SELECT NAME
BY
UPLOAD
ENDED
Or:
UPLOAD
FAILED
↑
↓
↑
↓
If the upload has
terminated successfully.
If some anomaly
has occurred during
the upload of the list.
ON DISPLAY
DESCRIPTION
OPERATION
Connect the small
cable provided with
the software FT1249/A
to terminals
TX / RX / -
( or D / D- if there
is an RS485 line).
Run the software FT1249/A.
Consult the in-line Guide
for the settings required.
Press the Upload
pushbutton in the
software FT1249/A.
The list will be loaded
in software FT1249/A.
10 = DEFAULT
0 =
Connection by means
of RS232 line
0
180
01
10
POSSIBILE VALUE
DEFAULT VALUE
PARAMETER
1=ITALIAN
2=ENGLISH
3=FRENCH
4=GERMAN
5=PORTUGUESE
6=DANISH
7=FINNISH
8=DUTCH
9=SPANISH
10=DEFAULT
(you will be requested to enter
the language the next time
module FT3072/A is turned on).
0 = Connection by means
of RS232 line
1 = Connection by means
of RS485 line
Value from 01 to 255
Value from 10 to 180. It express-
es the time in seconds of the
entry phone conversation.
Value from 01 to 99. It
expresses the time in seconds
of the door-opening relay.
Value from 0 to 10.
It expresses the time in
seconds of the reset wait
at the end of a telephone
conversation.
LANGUAGE
DOWNLOAD TYPE
ADDRESS RS485
AUDIO TIMING
DOOR LOCK TIME
RESET TIME
6) PARAMETER TABLE
The explanatory table of the configuration parameters of module FT3072/A is given below:
Содержание DIGI-2
Страница 1: ...D I G I 2 S Y S T E M T E C H N I C A L M A N U A L ...
Страница 17: ...TM 15 TM U P yellow green A L T O A L T O U P MIC U P 8 9 10 11 12 13 ...
Страница 18: ...TM 16 U P UP U P UP ALTO UP U P U P 1 2 14 15 16 SOLUTION A SOLUTION B ...
Страница 36: ...TM 34 2 3 1 6 5 4 5 Installation of monitor on desk support FT5712 ...
Страница 52: ...TM 50 System with 1 standard Series video entrance Diagram 1 Only required if using push to exit button ...
Страница 53: ...TM 51 TM System with 1 standard Series audio entrance Diagram 2 Only required if using push to exit button ...
Страница 54: ...TM 52 System with 2 standard Series video entrances Diagram 3 Only required if using push to exit button ...
Страница 55: ...TM 53 TM System with 2 standard Series audio entrances Diagram 4 Only required if using push to exit button ...
Страница 57: ...TM 55 TM ...
Страница 59: ...TM 57 TM ...
Страница 61: ...TM 59 TM ...
Страница 62: ...TM 60 Connection of a MAX 9 riser branches for each Mixer power supply FT4896 Diagram 8 ...
Страница 64: ...TM 62 Connection in cascade of several internal units up to 25 for branch from FT4896 Diagram 10 ...
Страница 65: ...TM 63 TM ...
Страница 80: ...TECHNICAL MANUAL 1 a edition 01 2008 Cod 22591745 ...