128
Appendix
Care/Maintenance interval
Daily Weekly 4 months 12 months
Shut-off valve/feeding pump
•
Open shutoff valve/feeding pump, clean; replace valve membranes
with support rings if necessary.
Powder conveyance
•
Check powder discharge opening for foreign bodies.
•
Calibrate, at least for every new MP delivery.
•
Empty powder conveyance and check for correct function.
•
Perform basic cleaning.
Check detergent pump
•
Check pressure of hose pump and hoses, and visually inspect intake
side of pump for damage and wear; clean if necessary.
•
Replace pump hose.
Detergent tank
•
Check whether detergent tank is filled, top up if necessary.