33

Please open your box very carefully and take out all the components.

Parts List

1

2

3

4

5

5A

5B

6

7

8

9

10

11

12

13

14

15

SCF015BRA

SCF015SCR-CH, BB

SCF002CON

SCF02118REC

SCFROD95-BB, BN

SCFPIN

SCFCLIP

SCF021CAN-BB, BN

SCF021YOK-BB, BN

SCF021MOT-BB, BN

SCF021HUB-BB, BN

SCF02118BLA-BB, BN

SCF021BLAS

SCFREM

SVCCI

SCF021SHA

SCF021BLB

 

Part # 

Items 

Drawing 

Description 

Quantity

Pack with 3 Wire Connectors, 2 Metallic 

Washers and 4 Spring Washers

Mounting Bracket (1) with

2 Screws (2)

Remote Control Receiver

Down Rod (5) with

Pin (5A) and

Clip (5B)

Canopy

Yoke Cover

Motor Assembly and Chandelier Body

Hub Cover

Fan Blades

Pack of 13 Blade Screws and Washers

3.5W Edison LED Bulbs

Glass Shades

Remote Control and Holder

Voice Control Centre (VCC I)

1

1

1

1

1

1

1

1

4

1

12

12

1

1

Содержание VOCE CF02118

Страница 1: ...VOICE ACTIVATED CEILING FAN CF02118 INSTRUCTION MANUAL...

Страница 2: ...hone remote nor any other communication assistant 2 You have the flexibility to control multiple fans that are in the same area using your voice Or control them independently if you want 3 Bluetooth V...

Страница 3: ...hen mounted directly to the building structure appliance installation shall not expose combustible material and do not install the appliance to a ceiling with combustible finish The installation of th...

Страница 4: ...BB BN SCF021BLAS SCFREM SVCCI SCF021SHA SCF021BLB Part Items Drawing Description Quantity Pack with 3 Wire Connectors 2 Metallic Washers and 4 Spring Washers Mounting Bracket 1 with 2 Screws 2 Remote...

Страница 5: ...5B 12 13 14 7 10 Stop Ladder Philips Screw Driver Pliers Wire Stripper Measuring Tape Electrical Tape Suitable For Use in Damp Locations Net Weight 8 4Kg 18 5lb If you find any part missing please cal...

Страница 6: ...h of the blades WARNING To avoid risk of personal injury do not bend the brackets or the blades during installation cleaning etc WARNING To reduce the risk of fire electric shock or personal injury mo...

Страница 7: ...any wall or object Make sure that your box is properly grounded and has either a green or a bare wire WARNING The electrical outlet box should be clearly marked Suitable for Fan Support Failure to do...

Страница 8: ...are not twisted and aligning the holes for the pin on the Down Rod with the holes in the motor Yoke Insert Pin all the way through and put the Clip in place Secure tightly the 2 Set Screws and Nut Lo...

Страница 9: ...Gently insert the receiver into the Mounting Bracket with the flat part towards the top Carefully push wires and wire connectors into the electric box leaving the antenna outside of the Mounting Brac...

Страница 10: ...ing Hub Cover and Lights Insert Blade in the side slot in the Motor Assembly Be sure that the blade part marked This Side Up is towards the ceiling Take 3 Blade Screws from Pack of screws 11 and pre i...

Страница 11: ...stop the fan and go to the trouble shoot section Press 6 in your remote control The fan should move on to a high speed and you should feel a strong breeze going from ceiling to floor If the fan wobble...

Страница 12: ...the first time it will say Welcome to FORNO VOCE Depending on the room you are placing me please say now either FORNO Home FORNO Dining or FORNO Bedroom Action You need to say out loud FORNO Home FORN...

Страница 13: ...h Speed or goes to High Speed from whatever speed it is at Ceiling Fan turns On at Medium Speed or goes to Medium Speed from whatever speed it is at Ceiling Fan turns on at Low Speed or goes to Low Sp...

Страница 14: ...other FORNO devices that you may purchase The QR code below will take to the corresponding site Download the App and register your product following the App instructions This is important for Warranty...

Страница 15: ...ence by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit di...

Страница 16: ...our device is not locked nor muted Ensure that your VCC is under 33 10m away from your fan or closer if objects are in the way Ensure that you are under 16 5m away from your VCC when you are giving it...

Страница 17: ...att Airflow 1 197 Cubic Feet Per Minute Based on 12 cents per kWh and 6 4 hours use per day Your cost depends on rates and use Energy Use 15 Watts 10 50 Cost Range of Similar Models 18 or Smaller 4 Es...

Страница 18: ...me limitation may not apply to you Some states do not allow the exclusion of incidental or consequential damages so the above limitation may not apply to you This warranty gives specific legal rights...

Страница 19: ...mber If you received damaged appliance immediately contact the dealer or builder that sold you the appliance ______________________________________________ Date of Purchase ___________________________...

Отзывы: