![Forno Classico NAAPOLI 100 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/forno-classico/naapoli-100/naapoli-100_installation-and-operation-manual_2320456013.webp)
13
F
orno Classico residential
ovens are equiped with a
1/2
“ NPT gas connection located at the
rear left of the oven. Have a
licensed
gas
install
er
provide
the
hook
-‐
up
and
test
all
fittings
and
pipe
connections
for
leaks.
Use
approved
gas
leak
detectors
(soap
solutions
or
equivalent)
over
and
around
the
fittings
and
pipe
connectio
ns.
DO
NOT
USE
A
FLAME
TO
TEST
FOR
LEAKS!
Eurosit 630
is
the
gas
control
valve
that
operates
the
interior
burner.
The Eurosit 630
control valve is located beneath the
front right of the oven.
NOTE
: the gas valve is shipped in the
off
position.
The
manifold
pressure
test
port
fo
r
the
burner
gas valve
is
a
plugged
tap
located
at
the
base
of
the
gas valve body.
The
burner
manifold
pressure
has
been
adjusted
and
tested
at
the
factory.
A
variety
of
factors
can
influence
this
pressure,
so
be
sure
to
test
the
burner
manifold
pressure
and
adjust
the
valve
as
necessary
to
ach
ieve
the
specified
pressure.
NOTE
: Maximum inlet gas pressure:
1/2
“ (
14
inches W.C.).
GAS SPECIFICATIONS
Residential
Oven Series
Installation, Operation & Maintenance
Forno Classico LLC
Phone:
(805) 895
-
2626
53
Aero Camino [email protected]
Goleta, CA 93117 USA www.fornoclassico.com
REQUIREMENTS: NATURAL GAS
Check to make sure that your pizza oven was made to use natural gas. If you are not positive that
you sp
ecified natural gas for your oven, please call or write Forno Classico before installing and
using natural gas as your fuel source. Using the wrong fuel source will damage your oven. A pizza
oven configured for LP gas will have orifices that are differen
t than an oven made for natural gas.
If you specified natural gas, your oven was shipped with a regulator to be
used
during the
installation of your oven. You or a gas technicia
n must provide the correct connector and pipe.