Maintenance manual | Electro-pneumatic sliding dampers
www.formula-air.com
11
Step 2 : Repeat for the other side of the cylinder. Then repeat to the other cylinder (if there is a second cylinder
on the damper).
Step 3 : Connect the air hose supply to the male stud connection on the other side of the electro-pneumatic
solenoid valve (the side with the two regulators).
CAUTION !
We recommend using 6 Bar compressed air. DO NOT EXCEED 8 Bar !!
3.5.
Mounting the reed sensors on the cylinders (optional)
3.5.1 Mounting the reed sensors on the ROUND cylinder (optional)
Step 1 : place reed sensor strap around the cylinder body, place the reed sensor inside it.
Step 2 : Tighten the small screw on the head of the strap to hold it in place in the desired position.
3.5.2 Mounting the reed sensors on the SQUARE cylinder (optional)
Step 1 : Slide the reed sensor in the slits along the side of the cylinder.
Step 2 : Tighten the small screw on the reed sensor body to hold it in place at the desired position.
NOTE :
To ensure proper functioning, make sure that the reed sensors are placed at maximum 3 cm from the
edges of the cylinder body.
Reed sensor
≈ 3 cm
Reed sensor
≈ 3 cm