19
_________________________________________________________________________________
5.6 Replacement of the
rocker switch
The new main rocker switch consists of a power socket, fuse holder and an
integrated fuse element.
To replace the main rocker switch the the blade receptacles must be removed.
Then the main rocker switch unit need only be pressed on from inner surface
(straight plates needs to be pressed lightly).
5.7 Maintenance of the motor-drive mechanism
The motor-drive mechanism is basically maintenance free
.
The drive has
automatic belt tension and a safety clutch.
If the motor-drive mechanism is defective, the motor or the conv
e
y
o
r rubber
belt needs to be replaced!
Consult a technician or authorised representative!
5.8 Replacement of the fuse
The fuse is located in the main rocker switch
and c
an be opened with a small screw
driver. Remove the blown fuse and insert the new fuse according to the marked
specification (miniature fuse 5x20mm, 230VAC / 800mA or 115VAC / 1.6A).
Replacement fuse is provided into the rocker switch black
with on/off switch and fuse holder.
MyBinding.com
5500 NE Moore Court
Hillsboro, OR 97124
Toll Free: 1-800-944-4573
Local: 503-640-5920