12
The Envelope Sealer comes with a piling option as standard.
This option allows
for
seal
ing of
both normally stacked envelopes (see Picture 1, Page
13) as well as nested envelopes (see picture 2, Page 13)!
Settings for different letter thicknesses:
1.
In position 1 (
lower
) the basin support and separate pressure-plate unit
can be used for thickness up to 8 mm (all formats). For thickness above 8
mm up to 16 mm the basin support and
feed
separat
or plate
unit need
to shift in position 2
(upper)
.
2.
To shift the position, slightly release the knurled nut on the basin support
and lift the basin support together with the basin to the upper limit stop
(5mm) and fix the knurled nut again (picture 1+2, page 14). Use the same
process for the separate pressure-plate unit (picture 3+4, page 14).
Release knurled nut slightly and shift the separate pressure-plate unit to the
upper position (12 mm) and fix the knurled nut again.
The height adjustment of basin and separate pressure-
plate unit must be executed together to work properly!
4.2 Setting up and regulating the basin
The correct water level for the moistening rollers is controlled by circular
bubble
level
on the moisture basin by raising or lowering the two rear machine feet.
Once the water reservoir has been filled, it must be inserted into the ring of the
moisture basin so that the water reaches the top of the moisture roller, this is
adjustable by turning the rollers.
See also Paragraph 3.2, points 3...10
The water level in the moistening rollers is properly regulated, when it does not
reach the basin edge. Slowly aspirate the water with the rubber suction pear
from the top of the moistening roller to get a controlled and continued flow of
water from the reservoir.
The moistening roller top must always be in the water.
If the water level in the moistening rollers is too high, the mechanism must be
placed deeper and if the water level is too low, the mechanism must be
positioned higher, again by adjusting the two rear machine feet.
For example, when replacing the moisture tank the correct water level is set
when the circular
bubble
level is
locked
by means of its three fixing screws and
therefore the right water level is retained.
Despite correct regulation of the water level in moisture basin, the water may