17
The moisture tank should be unscrewed with the axis from the star grip
for cleaning and rinsed under running water after each run.
It is important to make sure that the moisture tank is not
deformed. It should rotate on its axis freely!
5.2 Replacing the conveyor belt
1.
Remove the first format slide (left), loosen the front left thumb screw
M5x18.
2.
Remove the
outfeed
tray box (right) at the rear 2xM6 with a
knurled nut, remove 2xM6 spring washers and 2x M6 body discs.
3.
Remove basin (loosen large star grip M10 to the right)
4.
At the separating wall, loosen and remove the spring pressure plate with
separating rubbers and belt.
5.
On the front wall to the left loosen M5x20 screw and U disc M5
(approximately 6-8 mm).
6.
On the front panel loosen first the 2 M6x16 screws on the left and right (left:
through hole in top side panel, right at
outfeed
tray).
7.
Tilt the front panel slightly forward, remove the left side cover, or in IR plate
tilt to the left (hanging with IR sensor on the cable).
8.
Remove body screws plus body discs completely M6x16 from the front panel
and pull the front panel forward.
9.
Pull off the cogged belt right over pulley clockwise with a little effort.
10.
Remove conveyor belt on both sides pulling forward over the drive rollers.
11. First place new conveyor belt right over the drive roller 5 cm, then left place
over roll, drive both back until the belt
is
at the edge of the belt rolls. Now with
light pressure push right behind the drive pulley conveyor rollers (leave
space for cogged belt)
12. Insert cogged belt on the pulley to the right (rotate counterclockwise in
the pulley-groove)
13. Replace front panel (support rollers under the belt)
14. Replace 2 M6x16 fixing screws, on the left with 3 body discs and on the
right with 1 body disc, do not tighten fully yet
!
15. Tilt the front panel slightly forward, hook left side panel.