Ford FG6250P Скачать руководство пользователя страница 27

 

FG6250P(E) - FG7750P(E) - FG9250P(E) 

EN 

Copyright © 2016 

P a g e

 | 

27

 

www.fordpowerequipment.co.uk 

32

 

TROUBLESHOOTING 

Problem 

Cause 

Solution 

Engine  is  running,  but  AC 
output is not available 

1.

 

Open circuit breaker 

2.

 

Poor connection 

3.

 

Defective cord set 

4.

 

Connected device is faulty 

5.

 

Fault in generator 

1.

 

Reset circuit breaker 

2.

 

Check and repair 

3.

 

Check and repair 

4.

 

Connect a device that is working 

properly 

5.

 

Contact service department 

Engine  runs  well  without 
load  but  bogs  down  when 
loads are connected 

1.

 

Short circuit in connected device 

2.

 

Generator is overloaded 

3.

 

Clogged fuel filter 

4.

 

Engine speed is too slow 

5.

 

Short circuit in generator 

1.

 

Disconnect device 

2.

 

See chapter “Don’t overload generator” 

3.

 

Clean or replace fuel filter 

4.

 

Contact service department 

5.

 

Contact service department 

Engine  will  not  start,  shuts 

down  during  operation,  or 

starts and runs rough. 

1.

 

ON/OFF switch set to “OFF” 

2.

 

Dirty Air filter 

3.

 

Clogged fuel filter 

4.

 

Stale fuel 

5.

 

Spark plug wire disconnected from spark plug 

6.

 

Bad spark plug 

7.

 

Water in fuel 

8.

 

Fuel valve is in “OFF” position 

9.

 

Over choking 

10.

 

Low oil level 

 

11.

 

Rich fuel mixture 

12.

 

Intake valve stuck open or closed 

13.

 

Loss of engine compression 

14.

 

Dead battery 

15.

 

Engine has flooded 

1.

 

Turn switch to “ON” 

2.

 

Replace Air filter 

3.

 

Clean or replace fuel filter 

4.

 

Replace fuel 

5.

 

Reconnect spark plug wire 

6.

 

Replace spark plug 

7.

 

Drain fuel tank and replace fuel 

8.

 

Turn fuel valve to “ON” position 

9.

 

Turn off choke 

10.

 

Fill crankcase to proper oil level & 

place generator on a level surface 

11.

 

Contact service department 

12.

 

Contact service department 

13.

 

Contact service department 

14.

 

Recharge or replace battery 

15.

 

Wait 5 minutes and recrank engine 

Engine lacks power 

1.

 

Generator is overloaded 

2.

 

Clogged fuel filter 

3.

 

Dirty Air filter 

4.

 

Engine needs servicing 

1.

 

See chapter “Don’t overload generator” 

2.

 

Clean or replace fuel filter 

3.

 

Replace Air filter 

4.

 

Contact service department 

Engine “hunts” or falters 

1.

 

Choke was removed too soon 

 

2.

 

Clogged fuel filter 

3.

 

Carburetor is running too rich or too lean 

1.

 

Move choke to middle position until 

engine runs evenly

 

2.

 

Clean or replace fuel filter 

3.

 

Contact service department 

 

 

Содержание FG6250P

Страница 1: ...FG6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 1 www fordpowerequipment co uk Fig A1...

Страница 2: ...FG6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 2 www fordpowerequipment co uk Fig A2...

Страница 3: ...s Fig 5 13 6 6 Recoil starting Fig 6 FG6250P FG7750P FG9250P 13 7 BEFORE STARTING 14 7 1 Adding Checking Engine Oil See Fig 7 15 7 2 Adding Fuel See Fig 8 15 7 3 Connecting Generator to an Electrical...

Страница 4: ...RK ARRESTOR SEE FIG 22 23 24 COOLING SYSTEM 23 25 CARBURETOR ADJUSTMENT 23 26 REPLACING FUEL FILTER SEE FIG 23 24 27 DRAINING FUEL TANK AND CARBURETOR 24 27 1 Draining the fuel tank 24 27 2 Draining t...

Страница 5: ...FG6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 5 www fordpowerequipment co uk 35 2 Maintenance Fout Bladwijzer niet gedefinieerd 36 SERVICE 30...

Страница 6: ...hting or serve as a back up power source during power outages It is not designed for professional use WARNING Please read and understand this operating manual before use and keep it for your future re...

Страница 7: ...t Guide 1 Spark Plug Wrench 1 Toolkit Phillips screwdriver 1 Combination Wrench 2 Funnel 1 Handles 2 Bushings Flanged 4 Outlets 3 Description Qty M8 x 50mm Hex Bolts for Handle 2 M8 Flanged Nuts for H...

Страница 8: ...pen Install a battery operated carbon monoxide alarm near bedrooms Keep exhaust from this unit from entering a confined area through windows doors vents or other openings When working in areas where v...

Страница 9: ...ank is empty with the fuel shut off valve turned to the off position WARNING Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which could result in injury To avoid rec...

Страница 10: ...t rated frequency and voltage WARNING Only use this unit as intended or serious injury or death could result Do not bypass any safety device Moving parts are covered with guards Make sure all protecti...

Страница 11: ...es 2 hair pins 2 washers 2 hub caps and 2 self tapping screws Raise or tilt generator so you can slide the wheel axle pin into the wheel the washer the wheel mounting hole located on the side of the f...

Страница 12: ...through the eyelet and tighten the screw and make sure the terminal will not touch any part of the frame Install the Red protection boot Fig 4 Repeat these steps for the Black Terminal WARNING Be car...

Страница 13: ...6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 13 www fordpowerequipment co uk 6 5 Installing the handles Fig 5 Fig 5 6 6 Recoil starting Fig 6 Attach the Recoil Starter Grip to the bracket Fig...

Страница 14: ...Wear Eye Protection Never Reverse Pole Connections Never turn the battery upside down DO NOT Smoke near the battery If electrolyte contacts the skin wash the area immediately with clean water If you...

Страница 15: ...vide space for fuel expansion Fig 8 CAUTION You must add oil before first operating this generator Always check oil level before each operation DO NOT USE E15 OR E85 FUEL IN THIS UNIT IT IS A VIOLATIO...

Страница 16: ...s Fig 9 WARNING Generator must be properly grounded to prevent electrocution Only operate generator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground...

Страница 17: ...Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which could result in injury To avoid recoil pull starter cord slowly until resistance is felt then pull rapidly fig 1...

Страница 18: ...enerator must be carried fold handle to the down position Never lift or carry generator by its handle CAUTION This product is heavy and requires several people to lift Lift and lower with your legs by...

Страница 19: ...oltage V displays the operating voltage of the generator Frequency F displays the frequency in hertz at which the generator is running The Run Maintenance Timer displays the time in hours and minutes...

Страница 20: ...heat created by the generator to prevent icing 1 Cut off all flaps 2 Cut off one of the long sides of the carton to expose the units muffler and exhaust Do not enclose the muffler exhaust 3 side of t...

Страница 21: ...lent Service Fuel Valve Inspect Muffler and Spark Arrester Check and Clean Air Cleaner Replace Air Filter Clean Cooling System 19CHANGING OIL SEE FIG 19 Run the Generator until the Engine is warm Plac...

Страница 22: ...ity for the engine Use the chart to select the best viscosity for the outdoor temperature range expected Note Below 40 F 4 C the use of SAE 30 will result in hard starting Above 80 F 27 C the use of 1...

Страница 23: ...nd slowly adjust to 0 700 mm 0 800 mm 028 031 if necessary Reinstall spark plug and tighten to Torque 22 0 26 9 Nm 16 20 ft lb Reconnect spark plug wire If spark plug is worn replace only with an equi...

Страница 24: ...ior to fill up Fig 22 Fig 23 27DRAINING FUEL TANK AND CARBURETOR To help prevent gum deposits in the fuel system drain the fuel from the tank and carburetor before storing the unit for long periods of...

Страница 25: ...ris if obstructed For short term storage start generator once every 7 days For semi long term storage add fuel stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system an...

Страница 26: ...500W 6500W 7500W Voltage 110V 230 240V AC Engine 420cc OHV 4 Stroke Air Cooled Engine Oil 10W30 1L Fuel Tank 25L Unleaded Gasoline 31NOISE Noise values measured according to relevant standard K 3 FG62...

Страница 27: ...cted from spark plug 6 Bad spark plug 7 Water in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compre...

Страница 28: ...ment co uk 33ELECTRICAL DIAGRAM RECOIL STARTER TYPE Alternator Alternator control panel control panel Engine Engine Engine switch connecting Bl Black Br Brown Y G Yellow Green 0 Orange Br R Brown Red...

Страница 29: ...ment co uk 34ELECTRICAL DIAGRAM ELECTRIC START TYPE Alternator Alternator control panel control panel Engine Engine Engine switch connecting Bl Black Br Brown Y G Yellow Green 0 Orange Br R Brown Red...

Страница 30: ...CE How to contact us To order parts receive warranty assistance or other services inquiries you can contact us by Please see contact data on the back of this manual Record the following information be...

Отзывы: