FG6250P(E) - FG7750P(E) - FG9250P(E)
EN
Copyright © 2016
P a g e
|
20
www.fordpowerequipment.co.uk
13
COLD WEATHER OPERATION
Under humid conditions where temperatures drop to 40°F (4°C) the carburetor and/or crankcase
breather system may begin to freeze. To prevent icing take the following steps:
1.
Replace any old fuel with clean, fresh fuel.
2.
Use synthetic 5W-30 or SAE 5W-30 engine oil. Check oil daily or after every 8 hours of use.
3.
Turn fuel valve to the open position.
4.
Ensure generator is serviced according to the maintenance schedule under “Maintenance” section
of manual.
5.
Shelter unit from elements.
14
TO BALANCE THE LOAD
To obtain the best output and performance of your Ford Generator it is best to make every effort to
balance the load on the outlets. Attempt to spread the load as evenly as possible by utilizing all
outlets and try to run higher wattage device on separate outlets when possible. For example; if you
have a device that draws 2,500W and a device that draws 2,000W, put one plug in the left duplex
receptacle and then plug the other device in the right duplex receptacle which would be a more
balance than placing both plugs in a single duplex receptacle putting 4,500W on one receptacle.
15
CREATING A TEMPORARY COLD WEATHER SHELTER
In an emergency, the original shipping carton can be used as a temporary shelter. The shelter
should hold enough heat created by the generator to prevent icing.
1.
Cut off all flaps.
2.
Cut off one of the long sides of the carton to expose the units muffler and exhaust. Do not
enclose the muffler / exhaust
3.
side of the generator.
4.
Slide carton over generator. If necessary, remove the wheel assembly for fit.
5.
Maintain 5 feet of clearance between the open side of box and other objects. The exposed side of
the box should face away from the wind and elements.
6.
Remove shelter when temperatures reach 40°F (4°C).
Regular maintenance will extend the life of this generator and improve its performance. The
warranty does not cover items that result from operator negligence, misuse, or abuse. To receive
full value from the warranty, operator must maintain the generator as instructed in this manual,
including proper storage.
WARNING! Before inspecting or servicing this machine, make sure the engine is
off and no parts are moving. Disconnect the spark plug wire and move it away
from the spark plug.
16
PRE-OPERATION STEPS
Before starting the engine, perform the following pre-operation steps:
Check the level of the engine oil and the fuel tank level.
Make sure the air filter is clean.
Remove any debris that has collected on the generator and around the muffler and controls. Use
a vacuum cleaner to pick up loose debris. If dirt is caked on, use a soft bristle brush.
Inspect the work area for hazards.
17
AFTER EACH USE
Follow the following procedure after each use:
Shut off engine.
Charge electric starter. (see Battery Charger for Electric Starter pg 15)
Store unit in a clean and dry area.