MAINTENANCE SCHEDULE
After First 5 Hours
Change Oil
After 8 Hours or Daily
Clean Debris
Check Engine Oil Level
Annually (25 hr Use)
Check and Clean Air Cleaner
Change Engine Oil (Service more often under dirty or dusty conditions)
Check Muffler and Spark Arrester
Annually (100 hr Use)
Service Spark Plug (Replace with NGK BP6ES, Champion N9YC or
equivalent)
Service Fuel Valve
Inspect Muffler and Spark Arrester
Check and Clean Air Cleaner, Replace Air Filter
Clean Cooling System
19
CHANGING OIL (SEE FIG.19)
Run the Generator until the Engine is warm.
Place generator on a level surface.
Remove the crankcase dipstick.
Place an oil pan underneath the oil drainage
bolt to
collect used oil.
Remove the oil drainage plug and allow oil to
drain
completely.
Reinstall oil drainage plug, tighten securely.
Carefully add SAE 10W-30 to empty
reservoir until
the oil reaches the
outer edge of the oil fill hole (Crankcase
Dipstick hole).
Replace crankcase dipstick.
Fig.19
Oil Fill & Dipstick
Oil drainage plug