44
BT1119-2 WSS
Aspect ratio data inserted as Y signals into line 23 of 625/50 analog signals.
S12M-1 VITC
Time code data inserted as SD-SDI Y signals.
*1
S12M-1 ATC
Time code data inserted as data packets into the ancillary data space of SDI signals.
*1
*1
The timecode selected under Output (see Section 4-2-10-3. Timecode) will be embedded.
4-2-10-3. Timecode
Output
Item
Default
Setting range
Description
FS 1-10
Pass
Pass
LTC In
TCG Out
Allows you to select a timecode to embed to SDI
output signals.
*1
Pass:
Uses the timecode embedded into SDI signals
without processing.
LTC In:
Embeds and outputs the input timecode via
the rear panel IN/OUT connector to the SDI output
signal.
TCG Out
: Embeds the timecode generated by the
Time Code Generator into SDI output signal.
*1
To embed a timecode into an SDI signal, set Embedding to Enable for S12M-1 VITC or S12M-1 ATC
(see Section 4-2-10-2
. “Ancillary Data Multiplexer”).
LTC Input / Output Setting
Item
Default
Setting range
Description
BNC
Input
Input
Output
Allows you to set the LTC IN/OUT connector on the
rear panel for input or output use.
Timecode is displayed above the input and output
buttons.
Input:
Displays the input timecode above the button.
Output:
Outputs the Timecode generator count.
Timecode Generator
Item
Default
Setting range
Description
Start (button)
-
-
Allows you to start counting the internally
generated timecode.
Stop (button)
-
-
Allows you to stop counting the internally
generated timecode.
Reset (button)
-
-
Allows you to reset the internally generated
timecode to 00:00:00:00.
Preset (button)
-
-
Allows you to set the timecode to the Preset
time.
Edit (button)
-
-
Allows you to edit Preset timecode settings.
Drop Frame
OFF
OFF
ON
OFF:
Outputs Non-drop frame timecode.
ON:
Outputs Drop frame timecode.