27
<Adjustable range per signal format>
Format
Adjustable range
Line
AVDL
Line(Minimum)
1080/59i
-1.5H to -0.5H
-6H to -0.5H
-1.2 H to -0.2 H (400 clk)
720/59p
-1.5H to -0.5H
-6H to -0.5H
-1.25 H to -0.25 H (400 clk)
1080/59p Level-A
-1.5H to -0.5H
-6H to -0.5H
-1.2 H to -0.2 H (400 clk)
1080/50i
-1.5H to -0.5H
-6H to -0.5H
-1.15 H to -0.15 H (400 clk)
720/50p
-1.5H to -0.5H
-6H to -0.5H
-1.2 H to -0.2 H (400 clk)
1080/50p Level-A
-1.5H to -0.5H
-6H to -0.5H
-1.15 H to -0.15 H (400 clk)
1080/23.98PsF
-1.5H to -0.5H
-6H to -0.5H
-1.15 H to -0.15 H (400 clk)
1080/24PsF
-1.5H to -0.5H
-6H to -0.5H
-1.15 H to -0.15 H (400 clk)
1080/59p Level-B
-3H to -1H
-11H to -1H
-1.2 H to -0.2 H (400 clk)
1080/50p Level-B
-3H to -1H
-11H to -1H
-1.15 H to -0.15 H (400 clk)
2x1080/59i Level-B
-3H to -1H
-11H to -1H
-1.2 H to -0.2 H (400 clk)
2x1080/50i Level-B
-3H to -1H
-11H to -1H
-1.15 H to -0.15 H (400 clk)
2x1080/29p Level-B
-3H to -1H
-11H to -1H
-1.2 H to -0.2 H (400 clk)
2x1080/25p Level-B
-3H to -1H
-11H to -1H
-1.15 H to -0.15 H (400 clk)
1080/59p Level-A
→
B
-3.5H to -2.5H
-8H to -2.5H
-3.2 H to -2.2 H (-2H - 400 clk)
1080/50p Level-A
→
B
-3.5H to -2.5H
-8H to -2.5H
-3.32 H to -2.32 H (-2H - 850 clk)
1080/59p Level-B
→A
-1.5H to -0.5H
-6H to -0.5H
-1.2 H to -0.2 H (400 clk)
1080/50p Level-B
→A
-1.5H to -0.5H
-6H to -0.5H
-1.15 H to -0.15 H (400 clk)
525/60
-1.5H to -0.5H
-6H to -0.5H
-1.4 H to -0.4 H (700 clk)
625/50
-1.5H to -0.5H
-6H to -0.5H
-1.4 H to -0.4 H (700 clk)
IMPORTANT
Note that 1080/59p or 1080/50p Level-B output signal that is converted from Level-A
requires more delay than other output signal formats. In such casem, 3H delay is
present in Line or AVDL Sync Mode, and 2H+400clk or 2H+850clk in Line(Minimum)
Sync mode.
Notes on configuring the Line (AVDL) / Line (Minimum) sync system (in case of
1080 /59i)
To synchronize video signals, adjust System Phase settings so that input signal timings fall in
allowable input timings, which differ depending on the Sync Mode setting and video signal
format as described below.
The difference between the FA-1010 input and output timings must be
-1.5H
to
-0.5H
, if
Sync Mode
is set to
Line
. The difference must be
-6H
to
-0.5H
, if set to
AVDL
.
-6H
-5H
-4H
-3H
-2H
-1H
0H
Allowable input
timing in AVDL
mode
Allowable input
timing in Line
mode
Allowable input
timing in Line
minimum mode
FA-1010
output
timing