106
To Use the internal power (500 mA, 5 VDC) for GPI outputs
(1) Power OFF the FA-1010.
(2) Remove the FA-1010 top plate by removing 3 screws on the top and 4 screws at each
side. Remove rack-ears if installed.
* Keep the removed screws, 11 in total, in a safe place for use when reinstalling the top
plate.
(3) Change a dipswitch on the FA-10GPI to
ON
for the outputs. (See the table below.)
In the figure below, "
□
" indicates the switch position.
For example, when using the internal power for
GPI OUT 1
, Set
Pin 1
in
S1
to
ON
.
Dipswitch
Pin no.
Default setting
Signal
S1
1
OFF
GPI OUT 1 (output)
2
OFF
GPI OUT 2 (output)
3
OFF
GPI OUT 3 (output)
4
OFF
GPI OUT 4 (output)
5
OFF
GPI OUT 5 (output)
6
OFF
GPI OUT 6 (output)
7
OFF
GPI OUT 7 (output)
8
OFF
GPI OUT 8 (output)
S2
1
OFF
GPI OUT 9 (output)
2
OFF
GPI OUT 10 (output)
(4) Reinstall the top plate and power on the unit.
S1
S2
GPI card
S1 and S2 dipswitches