19
2.4.
Operating data
Burner pressures must be verified after a three minute boiler operation time
KC 24
Function
Max. CH
input
(kW)
CH
output
(80-60°C)
[kW]
CH
output
(50-30°C)
[kW]
DHW
output
[kW]
Gas mains
pressure
[mbar]
Diaphragm
diameter
[mm]
Flue gas
CO
2
[%]
min
max
min
max
min
max
Methane Gas G20
23.7
6.5
23.1
7.3
24.8
7.3
28.0
20
7.2
8.8 ÷ 9.1
Propane Gas G31
23.7
6.5
23.1
7.3
24.8
7.3
28.0
37
5.3
9.8 ÷ 10.1
Table 3 – KC 24 model adjustment rates
Hot water supply ΔT 45°C = 8.9 l/min
Hot water supply ΔT 40°C = 10 l/min
Hot water supply ΔT 35°C = 11.5 l/min
Hot water supply ΔT 30°C = 13.4 l/min *
Hot water supply ΔT 25°C = 16.1 l/min *
*Note: mixed water to the tap
KC 28
Function
Max. CH
input
(kW)
CH
output
(80-60°C)
[kW]
CH
output
(50-30°C)
[kW]
DHW
output
[kW]
Gas mains
pressure
[mbar]
Diaphragm
diameter
[mm]
Flue gas
CO
2
[%]
min
max
min
max
min
max
Methane Gas G20
26.2
5.4
25.55
6.1
27.4
6.1
31.0
20
7.2
8.8 ÷ 9.1
Propane Gas G31
26.2
5.4
25.55
6.1
27.4
6.1
31.0
37
5.3
9.8 ÷ 10.1
Table 4 - KC 28 model adjustment rates
Hot water supply ΔT 45°C = 9.9 l/min
Hot water supply ΔT 40°C = 11.1 l/min
Hot water supply ΔT 35°C = 12.7 l/min
Hot water supply ΔT 30°C = 14.8 l/min *
Hot water supply ΔT 25°C = 17.8 l/min *
*Note: mixed water to the tap
KC 32
Function
Max. CH
input
(kW)
CH
output
(80-60°C)
[kW]
CH
output
(50-30°C)
[kW]
DHW
output
[kW]
Gas mains
pressure
[mbar]
Diaphragm
diameter
[mm]
Flue gas
CO
2
[%]
min
max
min
max
min
max
Methane Gas G20
31.4
8.7
30.63
9.6
33.2
9.6
35.4
20
8.4
8.8 ÷ 9.1
Propane Gas G31
31.4
8.7
30.63
9.6
33.2
9.6
35.4
37
6.0
9.8 ÷ 10.1
Table 5 - KC 32 model adjustment rates
Hot water supply ΔT 45°C = 11.3 l/min
Hot water supply ΔT 40°C = 12.7 l/min
Hot water supply ΔT 35°C = 14.5 l/min
Hot water supply ΔT 30°C = 16.9 l/min *
Hot water supply ΔT 25°C = 20.3 l/min *
*Note: mixed water to the tap
KR 24/KRB 24
Function
Max. CH
input
(kW)
CH
output
(80-60°C)
[kW]
CH
output
(50-30°C)
[kW]
Gas mains
pressure
[mbar]
Diaphragm diameter
[mm]
Flue gas
CO
2
[%]
min
max
min
max
Methane Gas G20
23.7
6.5
23.1
7.3
24.8
20
7.2
8.8 ÷ 9.1
Propane Gas G31
23.7
6.5
23.1
7.3
24.8
37
5.3
9.8 ÷ 10.1
Table 6 - KR 24/KRB 24 model adjustment rates
KR28/KRB 28
Function
Max. CH
input
(kW)
CH
output
(80-60°C)
[kW]
CH
output
(50-30°C)
[kW]
Gas mains
pressure
[mbar]
Diaphragm diameter
[mm]
Flue gas
CO
2
[%]
min
max
min
max
Methane Gas G20
26.2
5.4
25.5
6.1
27.4
20
7.2
8.8 ÷ 9.1
Propane Gas G31
26.2
5.4
25.5
6.1
27.4
37
5.3
9.8 ÷ 10.1
Table 7 - KR 28/KRB 32 model adjustment rates
KR 32/KRB 32
Function
Max. CH
input
(kW)
CH
output
(80-60°C)
[kW]
CH
output
(50-30°C)
[kW]
Gas mains
pressure
[mbar]
Diaphragm diameter
[mm]
Flue gas
CO
2
[%]
min
max
min
max
Methane Gas G20
31.4
8.7
30.63
9.6
33.2
20
8.4
8.8 ÷ 9.1
Propane Gas G31
31.4
8.7
30.63
9.6
33.2
37
6.0
9.8 ÷ 10.1
Table 8 - KR 32/KRB 32 model adjustment rates