37
Technical features and dimensions
2.6
Operating data
Burner pressures reported in the following page must be veriied after the boiler has been operating for 3 minutes.
Gas category: II2H3P
Fuel
Gas mains pressure
[mbar]
Nozzle [mm]
Diaphragm
diameter [mm]
Flue CO2 value [%]
Natural gas G20
20
3.05
-
9.0 ÷ 9.3
Propane Gas G31
37
2.50
-
10.0 ÷ 10.3
Tab. 2 Adjustment specifications 12 kW
Fuel
Gas mains pressure
[mbar]
Nozzle [mm]
Diaphragm
diameter [mm]
Flue CO2 value [%]
Natural gas G20
20
3.70
-
9.0 ÷ 9.3
Propane Gas G31
37
3.00
-
10.0 ÷ 10.0
Tab. 3 Adjustment specifications 24 kW
Fuel
Gas mains pressure
[mbar]
Nozzle [mm]
Diaphragm
diameter [mm]
Flue CO2 value [%]
Natural gas G20
20
4.00
-
9.0 ÷ 9.3
Propane Gas G31
37
3.30
-
10.0 ÷ 10.3
Tab. 4 Adjustment specifications 28 kW
Fuel
Gas mains pressure
[mbar]
Nozzle [mm]
Diaphragm
diameter [mm]
Flue CO2 value [%]
Natural gas G20
20
4.45
-
9.0 ÷ 9.3
Propane Gas G31
37
3.55
7.2
10.0 ÷ 10.0
Tab. 5 Adjustment specifications 32 kW