1.10 Programming mode for heating and water heater
To access zone 1 heating programme displaying or editing, press
button twice.
1. The display shows zone 1 symbol flashing, sun or moon symbols, bars on or off, respectively , at 00:00.Clock
lights display the programming connected to day 1 (Monday) and 00:00 bar is flashing.
2. Press OK to access zone programming function."PROG" wording starts flashing together with number 1
(Monday).
3. The required day can be selected by pressing CH +/- buttons.
4. Press OK to select the desired day.
5. Now you can associate the day/night level to the desired time of the day.
6. Whenever
/
button is pressed, the sun and moon symbols are alternatively activated (sun = day level;
moon = night level).
7. At the same time, close to the current time (flashing bar) clock bar comes on if the
icon is on, and turns off
the
icon is off.
8. Current time is indicated by both the clock and the flashing bar.
9. Press CH +/- buttons to move inside the different times of the day.
10. To program other days of the week or to program zone 2 and water heater, press
.
11. You will go back to the starting page.
Whatever part of the programme can be quit by pressing the
button twice.
The procedure to program zone 2 and water heater, is very similar to the one followed to program zone 1.
Press the "prog" button to access, in sequence, to the following 4 programmes: manual; zone 1; zone 2; water heater.
If ambient probes are connected, the "day temperature" and the "night temperature" levels will acquire the temperature value, and heating
will be active until the temperature measured by the ambient probe reaches the preset value for the different time slots.
When no ambient probe is connected, the two day/night levels will acquire the on and off values.
Heating is ON in the selected periods with the
icon, while it is OFF in the selected periods with the
icon.
In case of connection with "Open Therm" Remote Control, that zone shall not be managed by boiler boards, as it will be directly managed by
the remote control and, as a consequence, zone programming will be inhibited.